English – Denon DN-V1700 User Manual
Page 31
ENGLISH
31
2 Label format
• Label lines may consist of any character strings of up to 8 characters beginning with a sharp (“#”) (maximum 9 characters
including the “#”).
• The sharp is omitted when specified as such parameters as “GOTO”, “ONKEYGO”, or “ONBREAK”.
• The characters that can be used in label names are capital letters “A to Z”, small letters “a to z” and numbers “0 to 9”.
2 Parallel remote terminal
During script playback, parallel remote terminal pins 1 to 6, 11 and 12 function as keys 1 to 8, and can be used with the script
command “ONKEYGO”, for example.
2 List of script commands
(“n” refers to an integer)
Command
@
0
1
comment
Format
;
Description
Comment
0
2
play
PLAY
Playback of 1 or 2 files. The script does not move to the next step unless the file is
played to the file end
0
3
play standby
PLAYRDY
Preparation for file playback
0
4
play start
PLAYGO
Start playback of file for which the play standby mode is set from the specified TC
0
5
end
END
End/change script file execution
0
6
pause
PAUSE
Set pause mode (screen blacked out)
0
7
still
STILL
Set pause mode (still picture displayed on screen)
0
8
stop
STOP
Stop playback (still picture displayed on screen)
0
9
audio control
@
AUDIO
Switch audio output on and off
10
video control
@
VIDEO
Switch video output on and off
11
goto
GOTO
Forced change of command sequence
12
vitc set
@
SETTC
Set SMPTE time code
13
wait
WAIT
Wait specified number of seconds or until specified time code
14
on key goto
@
ONKEYGO
Set a forced change of command sequence at the time of key input
15
on SMPTE-tc goto
@
ONSMPTCGO
SMPTE timer interruption
16
if day of week goto
@
IFDWKGO
Change command sequence according to day of week
17
on rtc goto
@
ONRTCGO
Real time timer interruption
18
on break goto
@
ONBREAK
Specify new processing position when an execution break command is received
19
osd display
@
OSDDISP
Switch user OSD display on and off
20
osd print
@
OSDPRT
Write 1 line of user OSD
21
osd attribute
@
OSDATT
Set user OSD attribute
22
osd clear
@
OSDCLR
Clear line(s) of user OSD
23
tc interrupt control
@
TCINT
Disable/enable time code interruption
24
rtc interrupt control
@
RTCINT
Disable/enable RTC interruption
25
com-port set
@
COMSET
Serial port communications mode setting
26
com-port put
@
COMPUT
Output 1 line from serial port
27
parallel out set
@
OUTPORT
Parallel remote output terminal setting
28
drive change
DRV
Change current drive
29
site command enable
@
SITECMD
Enable acceptance of site command
30
SNTP time calibration
TIMECAL
Time calibration by SNTP server
31
still mode set
@
STLMODE
Set screen display in still mode
32
variable set
@
SET
Set loop counter value
33
loop
LOOP
Loop according to loop counter and label
✽ “@” in the “@” column indicates commands for which “@” can be used.
34
write log file
WRITELOG
Output log to file