14 serial remote control terminal, English – Denon DN-V1700 User Manual

Page 23

background image

ENGLISH

23

2 Hard disk drive access lamp

The access lamp when a hard disk drive is added is “ACCESS HDD”.

PCC

ACCESS

HDD

2 The following shows the order of priority when the power is turned on.

When power turned on

PCC (PC card slot (drive))

Hard disk drive

None

PC card slot (drive) *1

Loaded

Current drive

HDD (hard disk drive)

Installed

Installed

*1) The current drive does not switch automatically to the HDD when the PC card is ejected.

14 SERIAL REMOTE CONTROL TERMINAL

The serial remote control terminal on the DN-V1700’s rear panel can be used to connect the terminal software of a computer, etc.,
allowing a wide variety of control possibilities through serial remote control. The terminal is compatible with both RS232C and RS422A
standards, selected with the selector switch on the rear panel.

Hardware specifications

D-sub female 9 pins

Standards

Connector type

8 bits

Data length

9,600 bps

Baud rate

None

Flow control

Asynchronous synchronization

Synchronization

None

Parity

Conforming to RS232C and RS422A

1 bit

Stop bit

1

5

6

9

1

2

3

4

5

6

7

8

Pin no.

_

Output

Input

_

_

_

Output

Input

_

TXD (RETURN)

RXD

_

_

GND

TXD

RXD (RETURN)

RS422A (selector switch pressed in)

_

Output

Input

_

_

_

_

_

_

TXD

RXD

_

GND

_

_

_

RS232C (selector switch popped out)

Signal name

Input/output

Signal name

Input/output

9

_

_

_

_

NOTES:
• Use a serial straight through cable for connection to a computer.
• Be sure to turn the power of both the DN-V1700 and the control device off when connecting the serial cable and switching

between RS232C and RS422A. Failure to do so could damage the DN-V1700 or the control device.
Be sure to switch to the proper RS232C or RS422A setting for the communications hardware specifications of the control device.

• Signals other than TXD and RXD (DTR signals, for example) cannot be used on the DN-V1700. If reception control of such signals

is being performed on the control device, take the necessary software or hardware measures on the control device.