30

E-Class

4.5.4 Label Alignment Troubleshooting


If you experience label alignment problems, the following table offers
possible causes and solutions.

Problem

Possible Cause

Solution


Attempting to
perform Label
Alignment results
in no paper
movement.


With the Present
Sensor enabled,
Label Alignment
cannot be
performed without
a Label Length.


¾

Set Label Alignment to AUTO,
press and hold FEED until
media moves for the automatic
length measurement.

~OR~

¾

Re-measure the Label
Alignment Length. Use Printer
Setup mode to enter the new
length. Print a Database
Configuration label to ensure
the new length has been set.