Assembling vy-10u (1 ~ 3) panels to vy-em, Ii ii ii – Aiphone VY-5EM User Manual
Page 12
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Assembling VY-10U (1 ~ 3) panels to VY-EM
VY-5EM or VY-10EM with VY-10U panel(s), are
made up for 15 to max. 40-call entrance panel.
Back box dimensions
VY station
High
Wide
Deep
VY-5EM, VY-10EM
250 mm
10 feet
VY-10EM + 1 VY-10U
20-call
240 mm
390 mm
16 feet
62 mm
VY-10EM-t-2VY-10U
30-call
10 feet
530 mm
21 feet
3 feet
VY-10EM-h3VY-10U
40-call
670 mm
27 feet
1. Loosen screws (7) on back of VY-5/1 OEM chassis.
2. Attach new junction bar (2) VYK-A20 ~ 40, aligning
on the ditch.
Fasten all screws, on VYK-A plate to unite.
3. On back boxes, before assembly, knock out a hole
on each facing side. Attach VY-10U box to VY-EM's
with 2 screws top and bottom.
4. Detach panel frames, using special screwdriver.
5. Loosen panel-fixing screws ( 6 - 1 0 ) and disconnect
VY-EMA/Y-IOU's to separate from chassis.
6. Mount the chassis (assembled) to back box.
7. Reconnect and mount VY-EM/VY-10U panels on
the chassis.
1 Loosen
Ditch
__
Ditch
Junction
bar
VY-10EM
back view
VYK-A20
^ ii ii ii
VYK-A20, adjustable
4. Detach
- 12-