A.2 Run Time Errors
The error codes, [-299 and -200], indicate that errors have taken place in the execution controller.
In this case, bit 4 of the event status register is set.
Errors take place when the following events take place.
• When the
• The program message cannot be executed because of the device status.
Table A-2 Error Messages of Run Time Errors
Appendix A SCPI Error Messages
Code
Message
Error Detection Condition
-220
Parameter error
An error was found in the parameter.
-221
Setting conflict
Although the setting is correct as a parameter, it cannot be set because of the
device status.
E x a m p le :
A self-diagnosis was attempted during measurement.
A rate greater than that of the interface was specified as the
final MUX stage.
-222
Data out of range
The numeric data has exceeded the device specifications.
E x a m p le :
SENSe : MEASure : PERiod 0, s
; SYSTem : MEMory : STORe 25
-223
Too much data
The length of the string data has exceeded the specified length.
E x a m p le :
The following setting was used when word data of 16 characters
was specified.
: SENSe : TELecom : PATTem : UWORd "11001100110011001"
-224
Illegal parameter value
Using the parameter received is disabled.
E x a m p le :
1. The character data comes outside the specified range.
: SENSe : TELecom : BRATe M15
2. The string data comes outside the specified range.
: CALCulate : DATA? "LAST ; EC ; CMI"
-240
Hardware error
The command cannot be executed because of hardware failure.
-241
Hardware missing
The command cannot be executed because the option is not mounted.