SECTION 6

CARING FOR YOUR MACHINE

REMO VINO AND REPLA CING BOBBIN CASE

CAUTION: Before cleaning or adjusting
the machine, remove plug from the socket
outlet.

• Raise presser foot and needle.

• Open slide plate and remove bobbin.

To remove the bobbin case, the needle
plate must be removed first.

• Lift needle plate (1) from right corner

and slide out from under foot.

TO REMOVE BOBBIN CASE

Push lever (2) toward you until it stops,

and hold in this position.

• Lift bobbin case up and guide it out

toward you, as shown.

TO REPLACE BOBBIN CASE

Push lever (2) toward you until it stops,

and hold in this position.

• Guide bobbin case into place, making

sure block (3) is all the way under metal
bracket

(4).

• Return lever (2) to locking position over

top of bobbin case.

NOTE: After locking case in place, be
sure it is not tight, but can move slightly.

• To replace needle plate, slide it

under pin (5) and push it to the left.

• Press needle plate down in place.

• Insert bobbin and close slide plate.