Fig. 2 6, Accessory mounting rack – Carrier 38QB User Manual
Page 3
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

I'-O" (305 mm)
GRAVEL APRON
Г-И" (584mm) DIAM
‘
marker
tape
(HIDDEN)
б" (152 mm)
THICK
CONCRETE MOUNTING PAD FOR 38QB0I5
2 - 6 " (762mm) DIAM
Fig. 2
6
" (152 mm)
THICK
CONCRETE MOUNTING PAD FOR 38QB0I8-060
- Accessory Mounting Rack
condition (Table 2). For requirements beyond 50 ft,
obtain information from loeal Carrier distributor.
If 1-1/8in. tubing is used (38QB042,048,060),
braze it to the accessory 1-1/8 x 3/4-in. suction
connection adapter (Carrier Part No. 28AU900061)
or to a correctly sized field-supplied adapter, then
make Compatible Fitting connections. Isolate inter
connecting tubing from framing and ductwork or
where tubing runs thru stud spaces, enelosed ceilings
or pipe chases. Use isolation type hangers. Fig. 3,
since rigid fastening transmits pulsations to struc
ture creating objectionable sound.
Fig. 3 — Refrigerant Line Hangers
Table 2 — Installation Data (Fig. 1)
UNIT 38QB
015
018
024
030
036
042
048
060
OPERATING WEIGHT
(l|))
140
179
185
187
, 197
229
240
252
DIMENSIONS
Diameter (ft-in.)
(mm)
Height (ft-in.)
(mm)
REFRIGERANT CONNECTIONS
Suction (ODF)
Liquid (ODF)
REFRIGERANT LINES
Suction (ODF)
Liquid (ODF)
‘May use 7/8-in (22 22-mm) accessory tubing package with slight capacity loss See Table 3
3