19eb selection data, 850 ton selections (2989 kw), 1000 ton selections (3517 kw) – Carrier 19 Series User Manual
Page 21: 900 ton selections (3165 kw), 1100 ton selections (3869, Legend, Cont)
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

19EB Selection data
850 Ton Selections (2989 kW)
(cont)
1000 Ton Selections (3517 kW)
ADJ LVG.
ADJUSTED LVG. CHILLED WATER
ADJ. LVG.
ADJUSTED LVG. CHILLED WATER
CONO WTR.
TEMPERATURE —
F(C)
COND WTR.
TEMPERATURE — F (C)
TEMP.
r 40
42
44
45
46
48
TEMP.
40
42
44 I 45 ! 46 ^
48
(F) i (C)
(4.4)
(5.6)
(6.7)
(7.2)
(7.8)
(8.9)
(F) < (C)
(4.4)
(5.6)
(6.7)
(7.2)
(7.8)
(8.9)
UN
85
85
83
83
83
83
UN
89
89
sF*
87
87
87
CS
71
71
47
47
45
43
CS
75
81
71
71
71
71
85 29.4
RE
12
12
500
500
500
500
85 i 29.4
RE
500
12
12
12
12
12
MS
DJ
DJ
DJ
DJ
DH
DH
MS
DL
DL
DL
DL
DK
DK
KW
588
575
592
574
551
522
KW
686
661
639
639
637
624
UN
85
85
85
85
85
83
UN
89
89
89
87
87
87
CS
73
71
71
71
47
45
CS
77
81
81
81
71
71
90 : 32.2
RE
12
12
12
12
500
500
90 ; 32.2
RE
500
12
12
12
12
12
MS
DL
DK
DK
DJ
DJ
DJ
MS
DN
DM
DL
DL
DL
DL
KW
643
603
592
591
594
577
KW
769
709
685
685
672
654
UN
85
85
85
85
85
85
UN
89
89
89
87
87
87
CS
73
71
71
71
71
45
CS
79
83
81
81
81
71
92.5 : 33.6
RE
12
12
12
12
12
500
92.5 ; 33.6
RE
500
12
12
12
12
12
MS
DL
DK
DK
DK
DK
DJ
MS
DP
DN
DM
DM
DM
DL
KW
661
625
610
606
598
589
KW
851
751
703
702
694
674
UN
85
85
85
85
85
83
UN
89
89
87
87
87
CS
73
73
71
71
71
71
CS
83
73
81
81
71
95 ; 35.0
RE
12
12
12
12
12
12
95 ; 35.0
RE
*
12
12
12
12
12
MS
DL
DL
DK
DK
DK
DK
MS
DN
DN
DM
DM
DM
KW
686
667
631
622
617
613
KW
773
752
730
716
694
UN
85
85
85
85
85
83
UN
89
89
87
87
CS
75
73
73
73
71
71
CS
83
83
83
73
71
97.5 i 36.4
RE
12
12
12
12
12
12
97.5
i
36.4
RE
*
12
12
12
12
12
MS
DM
DL
DL
DL
DK
DK
MS
DP
DN
DN
DN
DM
KW
728
687
675
669
636
631
KW
804
777
777
764
729
UN
85
85
85
85
85
85
UN
89
89
87
"
... 87
'
87
CS
75
75
73
73
73
71
CS
85
83
83
83
73
100
i
37.8
RE
12
12
12
12
12
12
100
;
37.8
RE
*
12
12
12
12
12
MS
DN
DM
DM
DL
DL
DL
MS
DP
DN
DN
DN
DN
KW
748
736
690
688
682
646
KW
850
804
803
792
766
900 Ton Selections (3165 kW)
1100 Ton Selections (3869
ADJ. LVG.
ADJUSTED LVG. CHILLED WATER
ADJ LVG.
ADJUSTED LVG. CHILLED WATER
COND. WTR.
TEMPERATURE -
F(C)
COND. WTR.
TEMPERATURE —
F(C)
TEMP.
40
42
44
45 1 46
48
TEMP.
40
42
44 r
4 5
46
48
(F) i (C)
(4.4)
(5.6)
(6.7)
(7.2)
(7.8)
(8.9)
(F) ; (C)
(4.4)
(5.6)
(6.7)
(7.2)
(7.8)
(8.9)
UN
85
85
85
85
85
83
UN
89
89
89
CS
81
71
71
71
25
45
CS
73
81
71
85 ; 29.4
RE
12
12
12
12
500
500
85 : 29.4
RE
*
*
*
500
12
12
MS
DK
DK
DJ
DJ
DJ
DJ
MS
DL
DM
DL
KW
626
604
595
588
587
582
KW
680
693
676
UN
85
85
85
85
85
85
UN
89
89
89
CS
73
71
71
71
71
71
CS
75
81
81
90 : 32.2
RE
12
12
12
12
12
12
90 ; 32.2
RE
*•
*
*
500
12
12
MS
DL
DL
DK
DK
DK
DK
MS
DN
DM
DM
KW
684
649
626
619
613
600
KW
748
739
718
UN
85
85
85
85
85
85
UN
89
89
89
CS
83
73
71
71
71
71
CS
75
81
81
92.5 ; 33.6
RE
12
12
12
12
12
12
92.5 : 33.6
RE
*
*
*
500
12
12
MS
DM
DL
DL
DK
DK
DK
MS
DN
DN
DM
KW
708
686
643
637
631
618
KW
776
772
740
UN
85
85
85
85
85
85
UN
89
89
CS
75
73
73
71
71
71
CS
73
81
95 : 35.0
RE
12
12
12
12
12
12
95 i 35.0
RE
*
*
*
*
12
12
j
MS
DN
DM
DL
DL
DL
DK
MS
DP
DN
______
i
______
1
KW
747
703
691
657
642
637
I
KW
839
762
UN
85
85
85
85
85
85
UN
89
89
;
CS
75
73
73
73
83
71
CS
77
81
97.5 ! 36.4
RE
12
12
12
12
12
12
97.5 ; 38.4
RE
*
*
*
*
500
12
MS
DN
DM
DM
DM
DM
DL
MS
DP
DN
KW
774
735
707
701
712
649
KW
862
802
j
UN
85
85
85
85
85
85
UN
89
CS
77
75
73
73
73
71
CS
83
100 ; 37.8
RE
12
12
12
12
12
12
100 37.8
RE
*
*
*
*
*
12
MS
DP
DN
DM
DM
DM
DL
MS
DP
KW
834
773
734
719
714
673
KW
842
LEGEND
CS
— Compressor
GR
— Gear-Refrigerant
HE
— Heat Exchanger
KW
— Power Input
MS
— Motor Size
Refrigerant
Unishell
RE
UN
22