39-7/8

11/16-

-28-1/2

7/8

DIA

'-—»LL

ACCESSORY

1-3/4 DIA HOLE

GAS ENTRY

1/2 DIA HOLE"

THERMOSTAT
WIRE ENTRY

SIDE INLET

24-5/16

11/16-*-

H3/16

2-3/8

—-1-1/2 DIA

^ R.H. GAS ENTRY

7/8 DIA
ACCESSORY

1/2 DIA

THERMOSTAT
WIRE ENTRY

SIDE INLET

-11/16

NOTE: 2 ADDITIONAL 7/8 DIA KNOCKOUTS

ARE LOCATED IN THE TOP PLATE

NOTE; AIR DELIVERY ABOVE 1800 CFM REQUIRES THAT BOTH SIDES OF FURNACE
BE USED, OR A COMBINATION OF 1 SIDE AND BOTTOM, OR BOTTOM ONLY FOR
RETURN AIR.

INLET

-23-1/4-

-13/16

14-1/2

1-3/4

A88367

Table 2—Dimensions (In.)

UNIT SIZE

A

D

E

VENT CONN

SHIP. WT

045-08

14-3/16

12-9/16

12-11/16

4

122

045-12

14-3/16

12-9/16

12-11/16

4

124

070-08

14-3/16

12-9/16

12-11/16

4

132

070-12

14-3/16

12-9/16

12-11/16

4

134

091-14

17-1/2

15-7/8

16

4

150

091-16

21

19-3/8

19-1/2

4

154

111-12

17-1/2

15-7/8

16

4

160

111-16

21

19-3/8

19-1/2

4

166

111-20

24-1/2

22-7/8

23

4

184

136-16

21

19-3/8

19-1/2

5

178

136-20

24-1/2

22-7/8

23

5

194

155-20

24-1/2

22-7/8

23

5

204

Fig. 1—Dimensional Drawing

Before installing the furnace, refer to the current edition of the

NFGC. Canadian installations

must

be installed in accordance with

NSCNGPIC and all authorities having jurisdiction. For further

information, the National Fuel Gas -Code is available from Na­

tional Fire Protection Association Inc. Batterymarch Park, Quincy,

MA 02269, American Gas Association, 1515 Wilson Boulevard,

Arlington, VA 22209, or from Literature Distribution.
Installation must conform to the regulations of the serving gas

supplier and the local building, heating, and plumbing codes in

effect in the area in which the installation is made, or in the

absence of local codes with the requirements of the NFGC.

A

CAUTION

Application of this furnace should be indoors with special

attention given to vent sizing and material, gas input rate, air

temperature rise, and unit sizing. Improper installation or

misapplication of the furnace can require excessive servicing

or cause premature component failure.

A

WARNING

Improper installation, adjustment, alteration, service, mainte­

nance, or use can cause carbon monoxide poisoning, explo­

sion, fire, electrical shock, or other conditions which may

cause personal injury or property damage. Consult a qualified

installer, service agency, local gas supplier, or your distribu­

tor or branch for information or assistance. The qualified

installer or agency must use only factory-authorized and

listed kits or accessories when modifying this product. A

failure to follow this warning can cause electrical shock, fire,

personal injury, or death.

For accessory installation details, refer to the applicable instruction

literature.

NOTE:

Remove all shipping brackets and materials before

operating the furnace.

This furnace is designed for a minimum continuous return-air

temperature of 60°F db or an intermittent operation down to 55°F

db such as when used with a night setback thermostat. Return-air

temperature must not exceed a maximum of 85°F db.

WA