Fig. 1—dimensional drawing, A caution, A warning – Carrier WEATHERMAKER 8000 58WAV User Manual
Page 2
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
39-7/8
11/16-
-28-1/2
7/8
DIA
'-—»LL
ACCESSORY
1-3/4 DIA HOLE
GAS ENTRY
1/2 DIA HOLE"
THERMOSTAT
WIRE ENTRY
SIDE INLET
24-5/16
11/16-*-
H3/16
2-3/8
—-1-1/2 DIA
^ R.H. GAS ENTRY
7/8 DIA
ACCESSORY
1/2 DIA
THERMOSTAT
WIRE ENTRY
SIDE INLET
-11/16
NOTE: 2 ADDITIONAL 7/8 DIA KNOCKOUTS
ARE LOCATED IN THE TOP PLATE
NOTE; AIR DELIVERY ABOVE 1800 CFM REQUIRES THAT BOTH SIDES OF FURNACE
BE USED, OR A COMBINATION OF 1 SIDE AND BOTTOM, OR BOTTOM ONLY FOR
RETURN AIR.
INLET
-23-1/4-
-13/16
14-1/2
1-3/4
A88367
Table 2—Dimensions (In.)
UNIT SIZE
A
D
E
VENT CONN
SHIP. WT
045-08
14-3/16
12-9/16
12-11/16
4
122
045-12
14-3/16
12-9/16
12-11/16
4
124
070-08
14-3/16
12-9/16
12-11/16
4
132
070-12
14-3/16
12-9/16
12-11/16
4
134
091-14
17-1/2
15-7/8
16
4
150
091-16
21
19-3/8
19-1/2
4
154
111-12
17-1/2
15-7/8
16
4
160
111-16
21
19-3/8
19-1/2
4
166
111-20
24-1/2
22-7/8
23
4
184
136-16
21
19-3/8
19-1/2
5
178
136-20
24-1/2
22-7/8
23
5
194
155-20
24-1/2
22-7/8
23
5
204
Fig. 1—Dimensional Drawing
Before installing the furnace, refer to the current edition of the
NFGC. Canadian installations
must
be installed in accordance with
NSCNGPIC and all authorities having jurisdiction. For further
information, the National Fuel Gas -Code is available from Na
tional Fire Protection Association Inc. Batterymarch Park, Quincy,
MA 02269, American Gas Association, 1515 Wilson Boulevard,
Arlington, VA 22209, or from Literature Distribution.
Installation must conform to the regulations of the serving gas
supplier and the local building, heating, and plumbing codes in
effect in the area in which the installation is made, or in the
absence of local codes with the requirements of the NFGC.
A
CAUTION
Application of this furnace should be indoors with special
attention given to vent sizing and material, gas input rate, air
temperature rise, and unit sizing. Improper installation or
misapplication of the furnace can require excessive servicing
or cause premature component failure.
A
WARNING
Improper installation, adjustment, alteration, service, mainte
nance, or use can cause carbon monoxide poisoning, explo
sion, fire, electrical shock, or other conditions which may
cause personal injury or property damage. Consult a qualified
installer, service agency, local gas supplier, or your distribu
tor or branch for information or assistance. The qualified
installer or agency must use only factory-authorized and
listed kits or accessories when modifying this product. A
failure to follow this warning can cause electrical shock, fire,
personal injury, or death.
For accessory installation details, refer to the applicable instruction
literature.
NOTE:
Remove all shipping brackets and materials before
operating the furnace.
This furnace is designed for a minimum continuous return-air
temperature of 60°F db or an intermittent operation down to 55°F
db such as when used with a night setback thermostat. Return-air
temperature must not exceed a maximum of 85°F db.
WA