beautypg.com

Carrier 58MSA User Manual

Service and maintenance instructions, Re g ist ered f ir m

background image

58MSA

4-Way Multipoise Fixed-Capacity

Condensing Gas Furnace

Service and Maintenance Instructions

For Sizes 040—120, Series 120 and 130

NOTE:

Read the entire instruction manual before starting the

installation.

This symbol

indicates a change since the last issue.

TABLE OF CONTENTS

SAFETY CONSIDERATIONS .....................................................1

GENERAL......................................................................................2

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS........2

CARE AND MAINTENANCE.....................................................2

Cleaning and/or Replacing Air Filter.......................................3
Blower Motor and Wheel Maintenance ...................................3
Cleaning Burners ......................................................................4
Cleaning Heat Exchangers........................................................5
Flushing Collector Box and Drainage

System ............................................................................................6

Servicing Hot Surface Ignitor ..................................................7
Electrical Controls and Wiring.................................................8
Checking Heat Tape Operation

(If Applicable) ................................................................................8

Winterizing................................................................................9

WIRING DIAGRAM.....................................................................9

TROUBLESHOOTING .................................................................9

SAFETY CONSIDERATIONS

Installing and servicing heating equipment can be hazardous due to
gas and electrical components. Only trained and qualified person-
nel should install, repair, or service heating equipment.

Untrained personnel can perform basic maintenance functions
such as cleaning and replacing air filters. All other operations must
be performed by trained service personnel. When working on
heating equipment, observe precautions in the literature, on tags,
and on labels attached to or shipped with the unit and other safety
precautions that may apply.

Follow all safety codes. In the United States, follow all safety
codes including the National Fuel Gas Code (NFGC) NFPA
54-1999/ANSI Z223.1-1999 and the Installation Standards, Warm
Air Heating and Air Conditioning Systems (NFPA 90B)

ANSI/NFPA 90B. In Canada, refer to the CAN/CGA-B/49.1- and
.2-M95 National Standard of Canada, Natural Gas and Propane
Installation Codes (NSCNGPIC). Wear safety glasses and work
gloves. Have a fire extinguisher available during start-up and
adjustment procedures and service calls.

Recognize safety information. This is the safety-alert symbol

.

When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury.

A93040

Fig. 1—Multipoise Furnace in Upflow Orientation

A98306

REGISTERED QUALITY SYSTEM

C

ar

rie

r Corporat

io

n

R

E

G

IST

ERED F

IR

M

IS

O

9001 #A28

83

®

EFFICIENCY

RATING

CERTIFIED

CERTIFIED

Visit www.carrier.com

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

4

Tab

6a 8a

PC 101

Catalog No. 535-80007

Printed in U.S.A.

Form 58MSA-4SM

Pg 1

10-00

Replaces: 58MSA-3SM