beautypg.com

Carrier UPFLOW 58BTA User Manual

For your safety

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

HEATING & COOUNG

58BTA

Upflow/Horizontal Oil Furnace

Installation, Start-up and Operating Instructions

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE

VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE.

DO NOT ATTEMPT TO START THE BURNER WHEN EXCESS OIL HAS

ACCUMULATED, WHEN THE FURNACE IS FULL OF VAPOR OR WHEN
THE COMBUSTION CHAMBER IS VERY HOT.

WARNING

For use with grade 2 Fuel Oil maximum. Do Not
use Gasoline, Crankcase Oil or any Oil containing
Gasoline!

CAUTION

Never burn garbage or paper in the heating systems
and never leave rags or paper around the unit.

CAUTION

These instructions are intended to be used by
qualified personnel who have been trained in
installing this type of furnace. Installation of this
furnace by an unqualified person may lead to
equipment damage and/or a hazardous condition
which may lead to bodily harm.

GENERAL

This furnace is a three position unit, in that it may be
operated in upflow, horizontal left-to-right, and horizontal

right-to-left air flow positions. Very few modifications are
required to change the furnace from one position to

another at the job site. The furnace is shipped in the

upflow configuration-instructions on changing to other

configurations are on page 6 of this document.

It is shipped as a packaged unit, complete with burner

and controls. It requires a line voltage (115VAC)
connection to the control box, a thermostat hook-up as
shown on the wiring diagram, oil line connection(s),
adequate ductwork, and connection to a properly sized
vent.

The air handling capacity of this furnace is designed for
cooling air flow. Refer to Figure 6 for the expected
airflows at various external duct static pressures.

Issue 9413

20142901 118

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book

14'

PC

101

Tab 6a 8a

Catalog No. 565-878

Printed in U.S.A.

Form 58BTA-1SI

Replaces; New