58DP,DR

Downflow Gas-Fired Natural-Draft Furnaces

58DP Series 150 and 160

58DR Series 130

Installation, Start-Up and Service Instructions

NOTE:

Read the entire instructions before starting the

installation.

INTRODUCTION

Before installing the furnace, refer to “Procedures for
Natural-Draft Gas-Fired Furnaces” (packaged with the
equipment) for information concerning combustion, venting,

piping, and other standeird installation practices. Further
reference is made to the current edition of the National Fuel

Gas Code NFPA No. 54-1988/ANSI Z223.1-1988.

Reference should also be made to the regulations of the
serving gas supplier and the local building, heating, plumb­

ing, or other codes in effect in the area in which the installa­
tion is made.

SAFETY CONSIDERATIONS

Installation and servicing of heating equipment can be haz­
ardous due to gas and electrical components. Only trained
and qualified personnel should install, repair, or service

heating equipment.

Untrained personnel can perform basic meuntenance func­
tions such as cleaning and replacing air filters. AU other
operations must be performed by trained service personnel,
when working on heating equipment, observe precautions in
the literature, tags, and labels attached to or shipped with
the unit and other safety precautions that may apply.

Follow all safety codes, including NFPA No. 54/ANSI
Z223.1-1988, National Fuel Gas Code. Wear safety glasses
and work gloves. Have fire extinguisher available during
startup and adjustment procedures and service call.

Recomized safety information: This is the safety-alert sym­
bol

A.

When you see this symbol on the furnace and in

instructions or manueils, be alert to the potential for per­

sonal injury.

Understand the signal word—DANGER, WARNING, or
CAUTION. These words are used with the safety-alert sym­
bol. DANGER identifies the most serious hazards which

will

result in severe personal injury or death. WARNING

on the other hand

could

result in personal injury or death.

CAUTION is used to identify unsafe practices, which would
result in minor personal injury or product and property
damage.

Each furnace is shipped from the factory completely assem­
bled with multispeed direct-drive blower and wired ready for
downflow indoor heating installation only. AU sizes feature
a printed-circuit board control center with easy-to-read, 24-

volt terminal strip to ensure proper connections.

Fig. 1—Model 58DP

Table 1—Clearances (In Inches)

(From Combustible Materials)

Sizes

050

075 thru 150

Sides—Single-Wall Vent

1

1

Type-B Double-Wall Vent

0

1

Back

0

0

Top of Plenum

1

1

Vent Connector—Single-Wall

6

6

Type-B Double-Wall

1

1

Front—Combustion Air*

6

6

Service

30

30

*The 6-inch front clearance is needed for combustion-air entry and

drafthood relief.

»■NOTE:

The furnaces covered by these instructions are

design-certified for use with the vent damper specified on
the furnace rating plate. See instructions packaged with the

vent deunper for its installation.

A CAUTION

Application of this furnace should be indoors with spe­
cial attention given to vent sizing and material, gas
input rate, air temperature rise, and unit sizing.
Improper installation or misapplication of the furnace
can require excessive servicing or cause premature com­

ponent failure.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

'' I ^

PC 101 Catalog No. 565-873

Printed in U.S.A. Form 58DP,DR-4Si 5/89 Pg 1