beautypg.com

Minit, Mline, Appendices ~ appendix e: serial commands – ClearOne AP400 User Manual

Page 60: Explanation, Return values

background image

Appendices

~ Appendix E: Serial Commands

56

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

MHP

This command changes or reports back the state of the high

pass filter for a microphone.

[DEVICE] MHP

Explanation

CH= 1-4

Parameter to apply to the specified

microphone channel

CH= *

Parameter to apply command to all

microphone channels

X=0

Parameter to set the state to OFF

X=1

Parameter to set the state to ON

X=Null

Parameter to return the current state

Return Values

The command will return the updated condition (On=1, Off=0)

of the high pass filter in the same format as the command.

MINIT

This command sets or reports the current setting for the

initialization string sent to the modem when in modem mode.

[DEVICE] MINIT

Explanation

STRING can be any character combination up to 30 characters.

If STRING is not specified the command returns the currently

assigned string. To specify no initialization string, set STRING

to “CLEAR.”

Return Values

The command will return the updated string in the same format

as the command was issued.

MLINE

This command changes or reports back how much gain is

applied to the microphone input. The three settings are 0dB,

25dB, and 55dB.

[DEVICE] MLINE

Explanation

CH= 1-4

Parameter to apply to the specified

microphone channel

CH= *

Parameter to apply command to all

microphone channels

X=1

Parameter to set the state to 55dB gain

X=2

Parameter to set the state to 25dB gain

X=3

Parameter to set the state to 0dB (line level)

X=Null

Parameter to return the current state

Return Values

The command will return the updated condition of the gain

applied in the same format as the command.