Interface wiring diagram, Connectivity communication module cat. 5150, Yz as src – Winco ASCO 300 Accessory Connectivity Module User Manual
Page 21

CHANGE
LETTER
ECN NO.
BY
APPD
DATE
PROPERTY OF ASCO POWER TECHNOLOGIES, L.P. USE PERMITTED FOR OUR WORK
ONLY. ALL RIGHTS OF DESIGN OR INVENTION ARE RESERVED
MANUFACTURING TOLERANCES TO BE IN
ACCORDANCE WITH ASCO PROCEDURE MP-I-003
FOR PLASTIC PARTS SEE MP-I-055
ASSEM. REF. NO.
THIRD ANGLE
PROJECTION
PROJECT NAME;
BY
DATE
DRAWN BY
CHECKED
DRAFTING
APPROVAL
FINAL
APPROVAL
SUBSIDARY DISTRIBUTION
COMPUTER GENERATED DRAWING
SCALE
FILE
_01
DWG. NO.
SIZE
SHEET
ECN
NO.
CHANGE
LETTER
BS
AE
CH
AG
AN
AV
AP
AM
AA
AC
AJ
PS
AS
AL
AR
YZ
AS
SRC
2 of 2
TABLE 1
Acceptable
Communication Cable
Standard 80°C
Belden 9842
Belden 9829
Alpha 6202C
Alpha 6222C
Plenum Rated
Belden 89729
Belden 82729
Alpha 58902
INTERFACE WIRING
DIAGRAM
2/04
4/03
4/03
207179
B
629855
None
Visio
FLORHAM PARK, NJ USA 07932
Ethernet Communication Cable
Type
10 BaseT
Known as
Twisted Pair
Max. Length
of Segment
328ft. (100 meters)
Max. Stations
per Segment
1024
Cable Type
UTP CAT3, 4, 5
Connectors
RJ-45
Cable Impedance/
Terminations
Belden P/N
(reference)
7882A
Refer to ASCO P/N 607577 for hub
See Table 1 RS485 4 wire 4000 ft. Max.
Ethernet cable
10 Base T
Max. 300 ft. Max.
Ethernet cable
10 Base T
Max. 300 ft. Max.
Ethernet cable
10 Base T
Max. 300 ft. Max.
Ethernet cable
10 Base T
Max. 300 ft. Max.
J3
J1
J2
CONNECTIVITY
MODULE
CAT.NO.5150
POWER
RX
TX
1 RX+
2 RX-
3 TX+
4 TX-
5 COM
J4
RS-485
Link
CH2
CH1
DIAG
Reset
TTL
Group 1
Controller
Address 1-32
9600 Baud
Series 300 Transfer Switch
J3
J1
J2
CONNECTIVITY
MODULE
CAT.NO.5150
POWER
RX
TX
1 RX+
2 RX-
3 TX+
4 TX-
5 COM
J4
RS-485
Link
CH2
CH1
DIAG
Reset
TTL
Power Manager
Xp
Address 1-32
9600 Baud
Group 1
Controller
Address 1-32
9600 Baud
Series 300 Transfer Switch
J3
J1
J2
CONNECTIVITY
MODULE
CAT.NO.5150
POWER
RX
TX
1 RX+
2 RX-
3 TX+
4 TX-
5 COM
J4
RS-485
Link
CH2
CH1
DIAG
Reset
TTL
Group 5
Controller
Address 1-32
19200 Baud
7000 Series Transfer Switch
J3
J1
J2
CONNECTIVITY
MODULE
CAT.NO.5150
POWER
RX
TX
1 RX+
2 RX-
3 TX+
4 TX-
5 COM
J4
RS-485
Link
CH2
CH1
DIAG
Reset
TTL
Power Manager
Xp
Address 1-32
19200 Baud
Group 5
Controller
Address 1-32
19200 Baud
7000 Series Transfer Switch
Power Manager Xp
19200 Baud
Power Manager Xp
for Gen, breaker, load or other
Address
Gen 33 - 43
Breaker 52
Load/other 1 - 32
J3
J1
J2
CONNECTIVITY
MODULE
CAT.NO.5150
POWER
RX
TX
1 RX+
2 RX-
3 TX+
4 TX-
5 COM
J4
RS-485
Link
CH2
CH1
DIAG
Reset
TTL
Ethernet cable
10 Base T
Max. 300 ft. Max.
Power Manager Xp
9600 Baud
Group7/7a
J3
J1
J2
CONNECTIVITY
MODULE
CAT.NO.5150
POWER
RX
TX
1 RX+
2 RX-
3 TX+
4 TX-
5 COM
J4
RS-485
Link
CH2
CH1
DIAG
Reset
TTL
Ethernet cable
10 Base T
Max. 300 ft. Max.
T+
T-
R+
R-
GND
11
12
13
14
15
Group 7/7A
p/n 459666-XXX
p/n 459667-XXX
Address 1-31
9600 baud
Ethernet cable
10 Base T
Max. 300 ft. Max.
J3
J1
J2
CONNECTIVITY
MODULE
CAT.NO.5150
POWER
RX
TX
1 RX+
2 RX-
3 TX+
4 TX-
5 COM
J4
RS-485
Link
CH2
CH1
DIAG
Reset
TTL
T+
T-
R+
R-
GND
11
12
13
14
15
Group 7/7A
p/n 459666-XXX
p/n 459667-XXX
Address1- 31
9600 baud
Group7/7a
See Table 1 RS485 4 wire 4000 ft. Max.
24 VDC 80 mA
16 AWG
Connectivity Communication Module
Cat. 5150
Cable Assy
ASCO P/N
629798-001
Cable Assy
ASCO P/N
629798-002
Cable Assy
ASCO P/N
629798-001
Cable Assy
ASCO P/N
629798-001
Cable Assy
ASCO P/N
629798-002
Cable Assy
ASCO P/N
629798-001
Cable Assy
ASCO P/N
629798-002
Cable Assy
ASCO P/N
629798-002
NT 4.0, Windows 2K, XP with
IE, Internet Explorer 5.0 or higher
Ferrite
Ferrite
ASCO P/N
754995
See Note 1
Ferrite
Ferrite
ASCO P/N
754995
See Note 1
Ferrite
Ferrite
ASCO P/N
754995
See Note 1
Ferrite
Ferrite
ASCO P/N
754995
See Note 1
Ferrite
Ferrite
ASCO P/N
754995
See Note 1
Ferrite
Ferrite
ASCO P/N
754995
See Note 1
Ferrite
Ferrite
ASCO P/N
754995
See Note 1
NOTE:
Ferrite, ASCO P/N 754995 MUST BE INSTALLED ON
CABLE WITHIN 1" OF DEVICE BEING CONNECTED.
R
R
R
R
R
R
R