Connectivity summary information – Winco ASCO 300 Accessory Connectivity Module User Manual
Page 20

CHANGE
LETTER
ECN NO.
BY
APPD
DATE
PROPERTY OF ASCO POWER TECHNOLOGIES, L.P. USE PERMITTED FOR OUR WORK
ONLY. ALL RIGHTS OF DESIGN OR INVENTION ARE RESERVED
MANUFACTURING TOLERANCES TO BE IN
ACCORDANCE WITH ASCO PROCEDURE MP-I-003
FOR PLASTIC PARTS SEE MP-I-055
ASSEM. REF. NO.
THIRD ANGLE
PROJECTION
PROJECT NAME;
BY
DATE
DRAWN BY
CHECKED
DRAFTING
APPROVAL
FINAL
APPROVAL
SUBSIDARY DISTRIBUTION
COMPUTER GENERATED DRAWING
SCALE
FILE
_01
DWG. NO.
SIZE
SHEET
ECN
NO.
CHANGE
LETTER
BS
AE
CH
AG
AN
AV
AP
AM
AA
AC
AJ
PS
AS
AL
AR
YZ
AS
SRC
1 of 2
INTERFACE WIRING
DIAGRAM
Connectivity Communication Module
Cat. 5150
4/03
4/03
4/03
207179
B
629855
None
Visio
FLORHAM PARK, NJ USA 07932
200698
4/03
AS
SRC
A
Note: Baud rates of connectivity module and all other devices
connected to it MUST BE SAME.
Factory default settings:
IP Address 169.254.1.1
Subnet
255.255.0.0
Gateway
0.0.0.0
Laptop computer
use to configure
Connectivity Module
J3
J1
J2
CONNECTIVITY
MODULE
CAT.NO.5150
POWER
RX
TX
1 RX+
2 RX-
3 TX+
4 TX-
5 COM
J4
RS-485
Link
CH2
CH1
DIAG
Reset
TTL
Power Manager Xp
19200 bps
TTL/RS-485
Protocol:
Addressing: 1 - 32 PM
33 - 43 PM Engine
52 PM Breaker
Group 1 Controller with or w/o
Power Manager XP
9600 bps
TTL
Protocol:
Addressing:
1 - 32 CP/PM
Group 7/7A
Controller
9600 bps
RS-485
with or w/o
PM Xp
9600 bps
TTL
Protocol:
Addressing: 1 - 31
Group 5 Controller
with or w/o
Power Manager Xp
19200 bps
TTL
Protocol:
Addressing: 1 - 32 CP/PM
Ethernet crossover cable
ASCO PN 629590-006
Connect to connectivity
module J3
Connectivity Module
mode setting jumper
Connectivity Module J1 & J2 (TTL) *
ATS's,
Protocol, 19.2K/9600 Bps
ATS's,
Protocol, 9600 Bps
PM’s,
Protocol, 9600 Bps
PM's
Protocol, 19.2K/9600 Bps
PM's
Protocol, 19.2K/9600 Bps(Add. 33-43)
PM's
Protocol, 19.2K/9600 Bps(Add. 52)
Connectivity Summary Information
Connectivity Module J3 (Ethernet)
PC’s
Connectivity Module J4 (RS-485)
ATS's,
Protocol, 9600 Bps
Serial Modbus RTU Protocol, 19.2K/9600 Bps
Serial Modbus RTU Protocol, 19.2K/9600 Bps
Serial Modbus RTU Protocol, 19.2K/9600 Bps
Serial Modbus RTU Protocol, 19.2K/9600 Bps
Device Connectivity to Connectivity Module
7000 series ATS with or w/o Power Manager Xp
Series 300 ATS with or w/o Power Manager Xp
Series 900 ATS with or w/o Power Manager Xp
Power Manager Xp
Power Manager Xp at Engines
Power Manager Xp at Circuit Breakers
Supported Third Party Devices
PC - NT 4.0, Windows 2K, XP w/Internet
Explorer 5.0 or higher
LED Description
Power indication.
Green/Amber.
Data receiving status.
Data transmit status.
Link status. Green.
Client connection status.
CH1-Green, CH2-Yellow.
Diagnostics. Red.
LED Function
Green- Ethernet, Amber- RS-485 only.
Set by Factory.
Blinks to indicate receiving data from clients
Blinks to indicate transmit data to clients
Solid on indicates an active Ethernet connection
Both blinks to indicate active clients
Off indicates no error.
Short blinks and then off indicates
clients write data to server.
Solid red indicates errors.
LED label
POWER
RX
TX
LINK
CH1, CH2
DIAG
Mode jumper settings:
Ethernet Mode - on the right two pins.
Upload Mode - on the left two pins.
Connectivity Module side view and
internal mode jumper settings
Third party device
19200/9600
RS-485
Protocol:
Serial MODBUS RTU
207179
1/06
AS
SRC
B