beautypg.com

Compaq AA-RHGWB-TE User Manual

Page 277

background image

Figure 9–13: Externally Terminated Shared SCSI Bus with HSZ50 RAID
Array Controllers at Bus End

KZPSA-BB (ID 7)

Network

Memory
Channel
Interface

Memory Channel

KZPSA-BB (ID 6)

Memory Channel

Member
System
2

Member
System
1

2

1

1

2

T

T

3

4

3

3

4

HSZ50

Controller A

Controller B

HSZ50

ZK-1597U-AI

Table 9–3 shows the components used to create the cluster shown in
Figure 9–12 and Figure 9–13.

Table 9–3: Hardware Components Used for Configuration Shown in Figure
8–12 and Figure 8–13

Callout Number

Description

1

BN21W-0B Y cable

2

H879-AA terminator

3

BN21K (or BN21L) cable

a b

4

H885-AA trilink connector

a The maximum combined length of the BN21K (or BN21L) cables must not exceed 25 meters.

b The cable between the H885-AA trilink connectors on the HSZ50s could be a BN21L-0B, a 0.15-meter cable.

9.4.3.2 Cabling an HSZ20 in a Cluster using External Termination

To connect a SWXRA-Z1 (HSZ20 controller) to a shared SCSI bus, follow
these steps:

1.

Referring to the RAID Array 310 Deskside Subsystem (SWXRA-ZX)
Hardware User’s Guide
, open the SWXRA-Z1 cabinet, locate the SCSI
bus converter board, and:

Remove the five differential terminator resistor SIPs.

Configurations Using External Termination or Radial Connections to

Non-UltraSCSI Devices 9–27