2.
At the HSG80, set multiple-bus failover as follows. Note that before
putting the controllers in multiple-bus failover mode, you must remove
any previous failover mode:
HSG80> SET NOFAILOVER
HSG80> SET MULTIBUS_FAILOVER COPY=THIS
____________________
Note
_____________________
Use the controller known to have the good configuration
information.
3.
Execute the SHOW CONNECTION command to determine which
connections have a nonzero offset as follows:
HSG80> SHOW CONNECTION
Connection
Unit
Name
Operating system
Controller
Port
Address
Status
Offset
!NEWCON49
TRU64_UNIX
THIS
2
230813
OL this
100
HOST_ID=1000-0000-C920-DA01
ADAPTER_ID=1000-0000-C920-DA01
!NEWCON50
TRU64_UNIX
THIS
1
230813
OL this
0
HOST_ID=1000-0000-C920-DA01
ADAPTER_ID=1000-0000-C920-DA01
!NEWCON51
TRU64_UNIX
THIS
2
230913
OL this
100
HOST_ID=1000-0000-C920-EDEB
ADAPTER_ID=1000-0000-C920-EDEB
!NEWCON52
TRU64_UNIX
THIS
1
230913
OL this
0
HOST_ID=1000-0000-C920-EDEB
ADAPTER_ID=1000-0000-C920-EDEB
!NEWCON53
TRU64_UNIX
OTHER
1
230913
OL other
0
HOST_ID=1000-0000-C920-EDEB
ADAPTER_ID=1000-0000-C920-EDEB
!NEWCON54
TRU64_UNIX
OTHER
1
230813
OL other
0
HOST_ID=1000-0000-C920-DA01
ADAPTER_ID=1000-0000-C920-DA01
!NEWCON55
TRU64_UNIX
OTHER
2
230913
OL other
100
HOST_ID=1000-0000-C920-EDEB
ADAPTER_ID=1000-0000-C920-EDEB
!NEWCON56
TRU64_UNIX
OTHER
2
230813
OL other
100
HOST_ID=1000-0000-C920-DA01
ADAPTER_ID=1000-0000-C920-DA01
!NEWCON57
TRU64_UNIX
THIS
2
offline
100
HOST_ID=1000-0000-C921-09F7
ADAPTER_ID=1000-0000-C921-09F7
!NEWCON58
TRU64_UNIX
OTHER
1
offline
0
HOST_ID=1000-0000-C921-09F7
ADAPTER_ID=1000-0000-C921-09F7
!NEWCON59
TRU64_UNIX
THIS
1
offline
0
HOST_ID=1000-0000-C921-09F7
ADAPTER_ID=1000-0000-C921-09F7
!NEWCON60
TRU64_UNIX
OTHER
2
offline
100
HOST_ID=1000-0000-C921-09F7
ADAPTER_ID=1000-0000-C921-09F7
!NEWCON61
TRU64_UNIX
THIS
2
210513
OL this
100
HOST_ID=1000-0000-C921-086C
ADAPTER_ID=1000-0000-C921-086C
6–56 Using Fibre Channel Storage