beautypg.com

Example 6–2: setting up the mirrorset (cont.) – Compaq AA-RHGWB-TE User Manual

Page 146

background image

Example 6–2: Setting up the Mirrorset (cont.)

HSG80>

HSG80> SHOW CROOT-MIR

11

Name

Storageset

Uses

Used by

------------------------------------------------------------------------------

CROOT-MIR

mirrorset

DISK30300

DISK40100

Switches:

POLICY (for replacement) = BEST_PERFORMANCE

COPY (priority) = NORMAL
READ_SOURCE = LEAST_BUSY

MEMBERSHIP = 2, 2 members present

State:

UNKNOWN -- State only available when configured as a unit

Size:

8378028 blocks

Partitions:

Partition number

Size

Starting Block

Used by

---------------------------------------------------------------------

1

418896 (

214.47 MB)

0

12

2

1256699 (

643.42 MB)

418901

13

3

3351206 (

1715.81 MB)

1675605

14

4

3351207 (

1715.81 MB)

5026816

15

HSG80> ADD UNIT D131 BOOT-MIR PARTITION=1 DISABLE_ACCESS_PATH=ALL

16

HSG80> ADD UNIT D132 BOOT-MIR PARTITION=2 DISABLE_ACCESS_PATH=ALL

HSG80> ADD UNIT D133 BOOT-MIR PARTITION=3 DISABLE_ACCESS_PATH=ALL
HSG80> ADD UNIT D141 CROOT-MIR PARTITION=1 DISABLE_ACCESS_PATH=ALL

HSG80> ADD UNIT D142 CROOT-MIR PARTITION=2 DISABLE_ACCESS_PATH=ALL

HSG80> ADD UNIT D143 CROOT-MIR PARTITION=3 DISABLE_ACCESS_PATH=ALL

HSG80> ADD UNIT D144 CROOT-MIR PARTITION=4 DISABLE_ACCESS_PATH=ALL

HSG80> SET D131 IDENTIFIER=131

17

HSG80> SET D132 IDENTIFIER=132
HSG80> SET D133 IDENTIFIER=133

HSG80> SET D141 IDENTIFIER=141

HSG80> SET D142 IDENTIFIER=142

HSG80> SET D143 IDENTIFIER=143

HSG80> SET D144 IDENTIFIER=144

HSG80> set d131 ENABLE_ACCESS_PATH = !NEWCON49,!NEWCON50,!NEWCON51,!NEWCON52

18

HSG80> set d131 ENABLE_ACCESS_PATH = !NEWCON53,!NEWCON54,!NEWCON55,!NEWCON56

Warning 1000: Other host(s) in addition to the one(s) specified can still

access this unit.

If you wish to enable ONLY the host(s)

specified, disable all access paths (DISABLE_ACCESS=ALL), then

again enable the ones specified

HSG80> set d131 ENABLE_ACCESS_PATH = !NEWCON61,!NEWCON62,!NEWCON64,!NEWCON65

Warning 1000: Other host(s) in addition to the one(s) specified can still

access this unit.

If you wish to enable ONLY the host(s)

specified, disable all access paths (DISABLE_ACCESS=ALL), then

again enable the ones specified

HSG80> set d131 ENABLE_ACCESS_PATH = !NEWCON68,!NEWCON74,!NEWCON76,!NEWCON77

Warning 1000: Other host(s) in addition to the one(s) specified can still

access this unit.

If you wish to enable ONLY the host(s)

specified, disable all access paths (DISABLE_ACCESS=ALL), then

again enable the ones specified

HSG80> set d132 ENABLE_ACCESS_PATH = !NEWCON49,!NEWCON50,!NEWCON51,!NEWCON52
.

.

.

HSG80> set d144 ENABLE_ACCESS_PATH = !NEWCON49,!NEWCON50,!NEWCON51,!NEWCON52

6–36 Using Fibre Channel Storage