beautypg.com

Operating conditions, Safety during operation, Notice – VACUUBRAND PC 3012 VARIO User Manual

Page 7

background image

Documents are only to be used and distributed completely and unchanged. It is strictly the users’ responsibility to check carefully

the validity of this document with respect to his product. Manual-no.: 999164 / 19/05/2009

page 7 of 75

Operating conditions

The pumps have no approval for operation in or for pumping of potentially

explosive atmospheres.

The pumps are

not suitable to pump

- unstable substances,

- substances which react explosively under

impact (mechanical stress)

and/or when being exposed to

elevated temperatures without air.

- self inflammable substances,

- substances which are inflammable without air and

- explosive substances.

• The pumps are

not suitable for pumping substances which may form deposits

inside the pump. Deposits and condensate in the pump may lead to increased tem-

peratures even to the point of excessing the maximum permitted temperatures!

• If there is a danger of

deposits in the pump chamber (check inlet and outlet of the

pump), inspect the pump chambers regularly and clean if necessary.

• The pumps are

not suitable for pumping dust and have no approval for opera-

tion below ground.

If pumping

different substances, it is recommended to purge the pump with air or in-

ert gas prior to changing the pumped media in order to pump out residues and to avoid

reactions of the pumped substances with each other and with the pump materials.

Take into consideration interactions and chemical reactions of the pumped me-

dia. Ensure that the materials of the wetted parts are compatible with the pumped

substances, see section ”Technical data”.

Safety during operation

Adopt suitable measures to prevent the release of dangerous, toxic, explosive,

corrosive, noxious or polluting fluids, vapours and gases. In case install an ap-

propriate collecting and disposal system and take protective action for pump and

environment.

Prevent any part of the human body from coming into contact with vacuum.

The user must take suitable precautions to prevent any formation of explosive

mixtures in the expansion chamber or at the outlet. In case of e.g. a diaphragm

crack, mechanically generated sparks, hot surfaces or static electricity may ignite

these mixtures. Use inert gas for gas ballast or venting if necessary.

Potentially explosive mixtures at the outlet of the pump have to be drained ap-

propriately, sucked off or diluted with inert gas to non-explosive mixtures.

Pay attention to the symbol ”hot surfaces” on the equipment. Adopt suitable

measures to prevent any danger arising from the formation of hot surfaces or

electric sparks. Provide a suitable protection against contact if necessary.

Ensure that the exhaust pipeline is always free and pressureless.

Ensure that the coolant outlet pipeline at the exhaust waste vapour condenser is

always free and that the coolant can flow off unobstructedly.


Pumping at high inlet pressure may lead to overpressure at the gas ballast valve.

Pumped gases or condensate might be pushed out in case the valve is open. If

an inert gas supply is connected, ensure that the inlet pipeline is not contaminated.

NOTICE

This manual is related to the following products: