Zone settings, P. 46) – Toa VM-3000 Series User Manual
Page 46

46
(1) Name
Sets the name for the zone.
Available Settings
16 alphanumeric characters (default name: Zone 1 – 90)
(2) Output setting button
Selects the output to be assigned to each zone.
Available Settings
Green: Output selected; Gray: Output not selected
(3) Selection button
Selects all outputs for an arbitrary zone.
Click any desired zone number (leftmost column of the table) to highlight its row. Pressing the "Selection"
button in this situation simultaneously selects all outputs in the highlighted row.
(4) Clear button
Clears all outputs selected for an arbitrary zone.
Click any desired zone number (leftmost column of the table) to highlight its row. Pressing the "Clear"
button in this situation simultaneously deselects all outputs in the highlighted row.
(5) Default button
Selects the speaker output with the same number as the zone number for all zones. (Example. Speaker
output 1 is selected for Zone 1, speaker output 2 selected for Zone 2.... similarly for all other zones.) The
screen above shows that the "Default" button has been pressed.
(1)
(2)
(3)
(4)
(5)
9. ZONE SETTINGS
Clicking the Menu item "Zone" button displays the Zone Setting screen.
Group multiple speaker lines for the VM-3000VA or VM-3000E and set the group as a broadcast zone. Up to
90 zones can be established.