Paging priority settings, Paging priority settings" on, P. 46 – Toa M-9000M2 CE-AU User Manual
Page 46: Are common, Is set

46
7.5. Paging Priority Settings
Select "Setting
Paging Priority Setting" from the menu on the main
screen or click the Priority indication button in the main view.
The setting screen is displayed in the Setting view.
Step 1. Select Priority 1 - 3 from the pull-down menu of the input channel to be used for paging applications.
(Priority 1 is the highest.)
Notes
• Be sure to set priorities for channels to be used for paging calls. Channels for which this priority setting is not
performed cannot be used for paging calls.
• ZP (zone paging) channels cannot be set to "-."
Step 2. Set channels not used for paging calls to "-."
Step 3. Check the VOX checkbox for the channels to be used for VOX.
Checking the "VOX" checkbox allows the following items to be set.
VOX threshold: - 40 to - 5 dB, in 5 dB units
Release time: 1 - 8 seconds (common to the gate release time)
Step 4. Set the Ducking level.
Levels that can be set: OFF (-∞), -50 dB, -40 dB, -30 dB, -20 dB, -10 dB, 0 dB
Priority indication button