beautypg.com

Toa TS-900 Series User Manual

Page 50

background image

Condition: Cable length between the Distributor and the TS-905 Infrared Transmitter/Receiver unit is

assumed to be 50 meters.

50

Central unit

Infrared Transmitter/Receiver units

TS-905

Distributor

L

L1

50 m

16.3.2. Example 2: When installing 4 TS-905 Infrared Transmitter/Receiver units using 1 coaxial cable

reaching from the Central unit (one 4-branch distributor connected):

1) Finding the maximum cable length using maximum allowable cable losses

Assuming that RG-59/U coaxial cable is used between the Distributor and the Infrared
Transmitter/Receiver unit, the cable loss between the two is calculated by the following equation:

Cable loss = 3.3 dB x (50 m / 100 m) = 1.65 dB

Since the Distributor's internal loss is 8.5 dB, the maximum allowable loss between the Central unit and the
Distributor becomes 9.85 dB (20 dB – 1.65 dB – 8.5 dB).

When RG-6/U coaxial cable is used between the Central unit and the Distributor, the length L1 between
the two is,

L1 = (Coaxial cable loss / its cable loss per 100 m )

= (9.85 dB / 2.7 dB) x 100 m
= 364 m

Maximum cable length L between the Central unit and the Infrared Transmitter/Receiver unit is
calculated by the following equation:

L

= L1 + 50 m
= 364 m + 50 m
= 414 m

Similarly calculated for other types of coaxial cables, the maximum cable length between the Central unit
and the Infrared Transmitter/Receiver unit is found in the following table.

RG-59/U

348 m

RG-6/U

414 m

RG-11/U

542 m