Toa TS-900 Series User Manual
Page 3

3
12. CHAIRMAN AND DELEGATE UNIT INSTALLATION AND SETTINGS
...... 41
13. CHAIRMAN AND DELEGATE UNIT POWER SUPPLY
13.1. BP-900 Lithium-Ion Battery
13.1.1. Inserting the lithium-ion battery ....................................................................... 42
13.1.2. Recharging ...................................................................................................... 43
13.2. AD-0910 AC Adapter .................................................................................................. 44
14. CENTRAL UNIT RACK MOUNTING
....................................................................... 45
15. INSTALLATION STATUS CONFIRMATION
.......................................................... 46
16. APPENDIX
16.1. Confirming the Wiring Design
16.1.1. Values necessary for calculating the loss ....................................................... 47
16.1.2. Values necessary for calculating the voltage drop .......................................... 47
16.2. Computational Equation
16.2.1. Finding the wiring loss ..................................................................................... 48
16.2.2. Finding the wiring voltage drop ....................................................................... 48
16.3. Design Examples
16.3.1. Example 1: When installing 4 TS-905 Infrared Transmitter/Receiver units
using 4 coaxial cables reaching from the Central unit: ................ 49
16.3.2. Example 2: When installing 4 TS-905 Infrared Transmitter/Receiver units
using 1 coaxial cable reaching from the Central unit
(one 4-branch distributor connected): .......................................... 50
16.3.3. Example 3: When installing each 4 TS-905 Infrared Transmitter/Receiver
units using 4 coaxial cables reaching from the Central unit
(four 4-branch distributors connected): ........................................ 52
16.3.4. Example 4: When installing 16 TS-905 Infrared Transmitter/Receiver units
using 1 coaxial cable reaching from the Central unit
(five 4-branch distributors connected): ........................................ 53
17. IF A FAILURE IS DETECTED
17.1. Chairman Unit TS-901 and Delegate Unit TS-902 ...................................................... 55
17.2. Central Unit TS-900 .................................................................................................... 56
17.3. Battery Charger BC-900 .............................................................................................. 56
18. SPECIFICATIONS
18.1. Central Unit TS-900 ................................................................................................... 57
18.2. Chairman Unit TS-901, Delegate Unit TS-902 ............................................................ 58
18.3. Microphone TS-903, TS-904 ...................................................................................... 58
18.4. Infrared Transmitter/Receiver TS-905, TS-907 ............................................................ 59
18.5. Lithium-Ion Battery BP-900 ........................................................................................ 59
18.6. Battery Charger BC-900 ............................................................................................. 60
18.7. AC Adapter AD-900 ................................................................................................... 60
18.8. Distributor YW-1022 (2-branch distributor), YW-1024 (4-branch distributor) .............. 61
18.9. Rack Mounting Bracket MB-TS900 ............................................................................ 61