Toa TS-800 Series User Manual
Page 39

39
11. CHAIRMAN AND DELEGATE UNIT INSTALLATION AND SETTINGS
Step 1. Set the unit address numbers for the
Chairman and Delegate units to be
used.
To perform this setting, rotate the rotary
DIP switches located on the bottom
side of the unit with a screwdriver.
Set for numbers [01] – [64] so that the
same number is not duplicated. Setting
[00] prohibits the unit from being used
for speech. To use the unit only for
monitoring purposes, set the address
number to [00]. (These switches are
factory-preset to [00].)
Step 2. Mount the microphone to the Chairman
or Delegate unit.
Step 3. Set the Interrupted Operation Reset and Priority Chime Disable functions using the in-line DIP switch
located on the bottom side of the Chairman unit.
Step 4. Turn on the same number of microphones on the Chairman and Delegate units as the maximum
number of simultaneous speakers set at the Central unit. Speaking into the microphone, adjust the
Central unit's Speech volume control to an appropriate level.
Step 5. Initiate speech from the microphones of all Chairman and Delegate units, and confirm that acoustic
feedback is not produced.
If feedback occurs, widen the distance between the Chairman unit and the Delegate unit or reduce
the output volume to prevent feedback.
Chairman or Delegate unit
Bottom side
(Inside of the cover)
UNIT ID
5
0
4
9
3
8
2
7
1
6
5
0
4
9
3
8
2
7
1
6
10
1
Tens digit
Units digit
CHAIRMAN UNIT TS-801
Chairman unit TS-801
or
Delegate unit TS-802
Microphone (standard) TS-903
or
Microphone (long) TS-904
ON
OFF
RESET
CHIME MUTE
ON
PRIORITY
RESTORE
NOT USE
1
2
3
Priority chime disable switch
Interrupted operation reset switch
(Inside of the cover)
Chairman unit
(bottom side)