Attaching a CC-4900 BNC Plug to the 5C-FB Cable
Step 1. Strip the jacket 10 mm from the end of the
coaxial cable.
Step 2. Unravel the braided shield and turn it back, then
peel away the aluminum cladding.
Step 3. Strip the dielectric 4 mm from the cable end.
Step 4. Disassemble the BNC plug as shown in the
figure at right.
Step 5. Insert the coaxial cable into the clamping fixture.
Step 6. Insert the clamping fixture assembly into the plug
and then solder the conductor.
Step 7. Insert the plug into the BNC connector.
Step 8. Clamp the connector by tightening the clamping
fixture.
Aluminum cladding
Braided shield
10 mm
Conductor
4 mm
Dielectric
BNC connector
Clamping fixture Plug
BNC connector
Clamping fixture
Solder.
Conductor
BNC connector
Clamping fixture
(Finished)
- D-2000 Series Installation (84 pages)
- DD-2000 Series Manual (24 pages)
- D-2000 Series Read Me First (12 pages)
- D-2012AS (2 pages)
- D-2012C (4 pages)
- D-901 (96 pages)
- CR-273 (20 pages)
- CR-413-6 (20 pages)
- EV-20R (20 pages)
- MP-1216 (8 pages)
- MB-WT3 (2 pages)
- MT-251H (1 page)
- F-2322C (12 pages)
- F-2852C (12 pages)
- SC-630 (2 pages)
- ES-0851 (4 pages)
- ES-C0651 (4 pages)
- F-1000B (18 pages)
- F-122C (12 pages)
- F-122CU (20 pages)
- F-122CU2 (16 pages)
- F-1300B (18 pages)
- F-1522SC (8 pages)
- AN-9001 (1 page)
- C-AL80 (16 pages)
- DP-K1 (28 pages)
- DP-K1 (102 pages)
- DP-L2 v.2.00 (28 pages)
- DP-SP3 Protocol (14 pages)
- DP-SP3 (24 pages)
- DP-SP3 (75 pages)
- E-232 (8 pages)
- AT-063AP (4 pages)
- BS-1015BSB (8 pages)
- BS-1030B (4 pages)
- BS-634 (4 pages)
- BS-1034EN (8 pages)
- BS-1110W (4 pages)
- BS-301B (8 pages)
- BS-301B AS (4 pages)
- MB-WT1 (1 page)
- S-D7300 (16 pages)
- VX-200SP-2 (24 pages)
- YA-1000A (1 page)
- ZM-9001 (2 pages)