TeeJet TASC-6500 User Manual
Page 9
95159
TASC 6200/6500
2-2
999-1511
DISPLA
Y SELECT
OR FUNCTIONS IN
THE
OPERA
TE MODE
DISPLA
Y SELECT
OR FUNCTIONS IN
THE
SET
-UP MODE
Speed
Area
L & Chemicals
V
ol.
Appl.
L & Chemicals
Appl.
Rate
L & Chemicals
% Rate
Carr
ier
Appl.
Rate
Carr
ier
V
ol.
Applied
Width
Distance
F
an RPM
Test
Speed
Scan
The current v
ehicle speed in MPH
The minim
um speed f
or the GSO function.
INC/DEC s
witch changes
.**
Accum
ulated area in hundreths of an acre (999.99 Maxim
um)*
Accum
ulated area in tenths of an acre (9999.9 Maxim
um) *
The amount of mater
ial actually discharged b
y channels 1,2,3 and L.
Units are not displa
yed.
The displa
y cycles through each position in
sequence unless a specific applicator is tur
ned on.
*
Calibr
ation n
umbers f
or applicator positions 1,2,3 and L.
Err
will
be displa
yed until an applicator position is selected.
When channel is
non-per
istaltic
, density is displa
yed.
When applicator is in split dr
iv
e,
all
booms m
ust be on to vie
w calibr
ation n
umber
. INC/DEC changes
.**
The target application r
ates (per acre) f
or channels 1,2,3.
The dis-
pla
y cycles through the activ
e postions
. INC/DEC changes b
y %.
***
The amount per acre to be applied b
y channels 1,2,3 and L.
Each chan-
nel m
ust be selected to ON and Alt-RA
TE in sequence
.
Tw
o r
ates are
prog
ramab
le f
or each channel.
Err
means incorrect s
witch setting.
**
The percent of prog
rammed r
ate at which all fiv
e channels are oper
ating.
INC/DEC changes b
y a pre-set percentage
. Alar
m beeps and flashes in-
dicating abnor
mal oper
ation.
Switching displa
y selector cancels
. ***
The percent of change in application r
ate caused b
y each actuation of
the INC/DEC s
witch when in the oper
ate mode
. INC/DEC changes
. **
The actual application r
ate b
y the con
ve
yor while the v
ehicle is applying.
Sho
ws the prog
rammed r
ate while v
ehicle is at rest.
INC/DEC changes
by
a percentage
. ***
The desired application r
ate f
or the Channel C
.
Tw
o r
ates are prog
ram-
mab
le
, the standard and the alter
nate r
ates
. Channel s
witch (C) m
ust
be on to set.
INC/DEC changes
. Product Density
, C OFF**
The accum
ulated amount discharged b
y the con
ve
yo
r. Reads pounds to
20,000 then shifts to hundredths of tons
. *
The channel C/product calibr
ation n
umber
. Calibr
ations should be v
er-
ified f
or an
y change in density
, flo
w
ability
, gate setting, etc.
INC/DEC
changes
. **
The activ
e boom width in f
eet.
Depends on the actual boom sections
tur
ned on.
Individual boom section prog
rammed widths (inches).
Displa
y cycles
through all sections unless one is tur
ned on.
Boom section C is test
boom width.
INC/DEC changes
. **
Accum
ulated distance
, miles after 5280.
*
The distance calibr
ation n
umber
. **
If no applicators are selected the displa
y indicates the pulses per re
v of the
fan sensor
. INC/DEC changes
. **
The speed the console will use f
or stationar
y tests of the system.
When
this s
witch sequence is selected, booms and applicators on, the system
will apply as if it w
ere tr
av
eling at this speed.
INC/DEC changes
. **
The current test speed.
INC/DEC changes
. **
The displa
y will scan oper
ational functions
, holding f
or about tw
o
seconds at each position.
Err
, in
valid s
witch setting.
SWITCH
SETTING
F
an RPM.
NO
TES:
*
Totals can be z
eroed in this mode
. **
V
alues are prog
rammab
le in this mode
.
***
V
alues changeab
le b
y a % increase or decrease
.
DISPLAY SELECTOR SWITCH POSITION TABLE