beautypg.com

TeeJet TASC-6500 User Manual

Page 13

background image

TASC 6200/6500

999-1511

13

M-T 96162

3.0 OPERATION

TASC is designed to operate automatically. It will accurately apply chemicals, according to the
instructions it has received from the operator. Before applying chemicals, it is important to verify that the
proper registers are zeroed, and that the proper calibrations are entered in the console.

3.1 NORMAL START UP AND OPERATION

3.1.1 CALIBRATION NUMBERS AND CONSTANTS

With all boom sections OFF, check to see that the proper calibration numbers and constants are
entered in the console. Pay particular attention to the density factors for Channel C and any
granular bin channels. Refer to the calibration section of the manual for specific help.

3.1.2 APPLICATION RATES

With all boom sections OFF, and the MODE SELECTOR switch in the SET-UP position, review the
application rates for each control channel. Remember to look at the alternate rates also.

3.1.3 ACCUMULATED AREA

The area accumulators can be reset to zero by selecting AREA and holding the DEC switch until
the display resets to zero. There are two accumulators, one in the OPERATE mode and one in the
SET-UP mode. The accumulators are zeroed independently. Keep track of field area in the
OPERATE AREA and keep track of total area in the SET-UP AREA.

3.1.4 ACCUMULATED AMOUNTS

Check the accumulated total discharge from each channel by viewing CARRIER, VOL. APPLIED
or L & CHEMICALS, VOL. APPLIED, while in the OPERATE mode. Use the DEC switch to reset
to zero.

3.1.5 OPERATE

TASC 6500 is ready to start applying. Set the MODE SELECTOR switch to OPERATE. Turn ON
the proper control channels. Select an appropriate display function, SCAN for example.

TASC-6500

CHEMICAL APPLICATORS

1

2

3

ON

OFF

Alt.-
RATE

%Rate

DISPLAY SELECTOR

Speed

Area

Width

Distance

Vol. Applied

Test

Speed

Fan RPM

Vol. Applied

Appl. Rate

Appl. Rate

OFF

SET- UP

DEC

ON

OPERATE

INC

.

1 2 3 4 5 6 7 8 9

BOOMS

Scan

MID-TECH

¨

MIDWEST TECHNOLOGIES,

INC.

RATE CONTROL CHANNELS

L & CHEMICALS

CARRIER

Mph

L

C

This manual is related to the following products: