This document is an addendum to revision 96233 of the TASC 6200/6500 operating
manual, PN-999-1511. It contains changes that will appear in revision 96162 of the
manual
Please make the following changes.
PAGE 2-2 / "L & Chemicals Appl." - CHANGE TO READ:
L & Chemicals Vol. Appl.
PAGE 2-2 / "L & Chemicals Rate" - CHANGE TO READ:
L & Chemicals Appl. Rate
PAGE 2-2 / "L & Chemicals Rate" - CHANGE SECOND COLUMN TO READ:
The target application rates (per acre) for channels 1, 2, 3, and L. The display cycles through the
active positions. INC/DEC changes by %. ***
PAGE 3-4 / PAR. 3.6.1 - ADD:
To view the actual application rate while in the manual override mode, switch the associated rate
rate switch to the alternate rate position. There must also be some ground speed.
PAGE 6-7 / PAR. 6.8/ITEM D - REPLACE WITH:
D. Turn the booms ON, Make sure there is some speed programmed into GSO (see page 6-5),
and turn the GSO switch on. Switch channel C rate switch ON. The conveyor will begin to
discharge.
PAGE 6-12 & FIELD CALIBRATION SHEET FOLLOWING PAGE 7-5 / SWITCH SETTINGS - CHANGE TO
READ:
Power ON
Mode selector SET-UP
Display Selector L & CHEMICALS, VOL. APPLIED
Channel 1, 2 or 3 ALT RATE POSITION
(Select only one channel at a time)
All booms ON
(for observing split drive channels)
PAGE 6-12 & FIELD CALIBRATION SHEET FOLLOWING PAGE 7-5 / FIRST PARAGRAPH - CHANGE:
Multiply the result by 1000 and multiply that result by the product density (pounds per FT
3
).
TO READ:
Multiply the result by 1,000,000 and multiply that result by the product density (pounds per FT
3
).