SerialGate User Manual
22
Menu
Default
Description
Latency
Time
0
This needs to be set when consecutive data from the given serial
port needs to be transmitted to socket at once.
For example, if 100 bytes of character string are to be transmitted
from the serial device to a server through SerialGate, bypass is set
to 0 for the latency time. Although it provides immediate sending
through SerialGate, the server could be received a lot parts of
divided packets.
If the latency time is not 0, SerialGate will wait for the time and
check new data. If there is new data, SerialGate repeatedly wait for
the time. Otherwise, SerialGate will transfer the buffered data, but it
could not run in real time.
(Range: 0 ~ 999)
Baud
Rate
9600 bps
Set the communication speed.
(Options: 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400,
57600, 115200, 230400 bps)
Data Bits
8
Data bits are set to 8 and cannot be changed.
Stop Bits
1
Set the stop bit (Options: 1, 2)
Parity
No
Set the parity bit. (Options: No, Odd, Even)
Flow
Control
None
Enable hardware controlled flow control of the data
(Option: None, RTS/CTS)