Solvline SG-3011PCL User Manual

Page 22

background image


SerialGate User Manual

22

Menu

Default

Description

Latency
Time

0

This needs to be set when consecutive data from the given serial

port needs to be transmitted to socket at once.

For example, if 100 bytes of character string are to be transmitted

from the serial device to a server through SerialGate, bypass is set

to 0 for the latency time. Although it provides immediate sending

through SerialGate, the server could be received a lot parts of

divided packets.

If the latency time is not 0, SerialGate will wait for the time and

check new data. If there is new data, SerialGate repeatedly wait for

the time. Otherwise, SerialGate will transfer the buffered data, but it

could not run in real time.

(Range: 0 ~ 999)

Baud
Rate

9600 bps

Set the communication speed.
(Options: 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400,
57600, 115200, 230400 bps)

Data Bits

8

Data bits are set to 8 and cannot be changed.

Stop Bits

1

Set the stop bit (Options: 1, 2)

Parity

No

Set the parity bit. (Options: No, Odd, Even)

Flow
Control

None

Enable hardware controlled flow control of the data
(Option: None, RTS/CTS)