Chapter 4. Setup
This chapter deals with connecting SG-3011PCL with other devise using the Ethernet and RS-
232/422/485 connection.
Before connecting to the network
The SG-3011PCL supports 10/100Mbps LAN/Ethernet and auto MDIX feature so that the users can
use either cross or direct cable.
Running the SG-3011PCL for the First Time
First, check the input voltage to the SG-3011PCL. It is recommended to use 5 VDC. The device can
handle up to 9 VDC. When the device boots, its RDY LED will stay on then starts blinking when
booting process is completed.
After the LEDs from the LAN port are blinking, the users can connect to the SG-3011PCL using any
web browser.
Network Access
In order to enter the web manager, the users require the default IP address to connect to the SG-
3011PCL which is 192.168.0.223. This initial static IP address can be changed from the web manager
to be a different static IP or a dynamic IP. It is recommended to use a static IP.
When the IP addressing of the SG-3011PCL is set to the dynamic IP or the users forgot the static IP to
connect to the web manager, the SGConfig utility can be used to retrieve the IP address of the SG-
3011PCL as shown in the next page.