Model no. 2, Rating plate 2, Ag 2 – Reznor B Parts Manuals User Manual
Page 2: Reznor

Form P-F/B (01-8-15), P/N 272436R5, Page 2
Example of a
Replacement Parts Tag
Replacement parts tags on unit
heaters are for your convenience
Example of a Rating Plate
Serial No. Explanation
Example:
BMC
94 9B
N
12345
1
2 3 4 5
Key:
1 = Date of manufacturer (see table on page 3)
2 = Type of Pilot (Refer to Form P-VALVES)
3 = Gas Valve (Refer to Form P-VALVES)
4 = Type of Gas (N = Natural; L = Propane)
5 = Consecutive number of heater made
(identification only)
Model No. Suffixes:
-S = Stainless steel heat exchanger
-2 = Two-stage gas valve
-E = Intermittent spark Ignition (NOTE: Spark
ignition required on all units effective 8/2008.)
-H = Factory equipped for high altitude operation
(NOTE: A change in 2004 allowing altitude
adjustment in the field eliminated the high-altitude
factory-equipped options.
Key to Rating Plate Information:
B = Model No. (Size)
C = Month and Year of Manufacture
D = Volts, Phase, Hertz and Maximum Total Input Amps
E = Type of Gas (Natural or Propane)
F = Burner Orifice Size
G and H = Elevation in Feet and Meters
I = Normal Input (BTUH) at Sea Level
J = BTUH Input Adjusted for Altitude
K = Thermal Output Capacity (BTUH) at Sea Level
L = BTUH Output Adjusted for Altitude
M = Minimum Input (BTUH) at Sea Level
N = BTUH Minimum Input Adjusted for Altitude
O = Normal Manifold Pressure (in. w.c.)
P = Minimum Gas Supply Pressure (in w.c.)
Q = Top Clearance (inches)
REZNOR
®
MERCER, PA. USA 16137
MADE IN MEXICO
UNIT
HEATER
NRTL
CATEGORY I
FOR INDUSTRIAL/COMMERCIAL USE ONLY
ANSI Z83.8 [
AA ] - [ A ] CSA 2.6 [ AA' ] - [ A' ] UNIT HEATER
MODEL [ B ] [ C ]
SERIAL NO.
[ D ] VOLTS [ D ] PH [ D ] HZ MAXIMUM TOTAL INPUT [ D ] AMPS
TYPE OF GAS: [ E ]
ORIFICE SIZE [
F ] DRILL HAS BEEN FACTORY ADJUSTED FOR USE
AT [
G ] FEET [ H ] METERS OF ALTITUDE.
SEA
LEVEL
ALT.
ADJUSTED
NORMAL INPUT
[
I ]
[
J ]BTU/HR.
THERMAL OUTPUT CAPACITY
[
K ]
[
L ]BTU/HR.
MINIMUM INPUT (-2 MODELS)
[
M ]
[
N ]BTU/HR.
NORMAL MANIFOLD PRESSURE
[
O ] IN.W.C.
MIN. PERMISSIBLE GAS SUPPLY PRESSURE FOR PURPOSE OF
INPUT ADJUSTMENT.
[
P ] IN.W.C.
CLEARANCES TO COMBUSTIBLE CONSTRUCTION: TOP-[
Q ],
FLUECONNECTION-6", LEFT SIDE-18", RIGHT SIDE-18",
BOTTOM-12" EXCEPT WHEN SUPPLIED WITH OPTIONAL
DOWNTURN NOZZLE BOTTOM IS 42"
FOR ALTERNATE INSTALLATIONS USE THE LATEST EDITIONS
OF THE APPROPRIATE STANDARD LISTED BELOW / INSTALL
IN ACCORDANCE WITH REQUIREMENTS OF ENFORCING
AUTHORITIES:
FOR AIRCRAFT HANGARS
USE STANDARD ANSI/NFPA 409
FOR PARKING STRUCTURES
USE STANDARD ANSI/NFPA 88A
FOR REPAIR GARAGES
USE STANDARD ANSI/NFPA 88B
THIS UNIT IS NOT FOR USE WITH DUCTS.
THIS UNIT IS NOT FOR USE WITH FILTERS.
THIS UNIT IS FOR USE WITH NATURAL GAS AND PROPANE. A
CONVERSION KIT AS SUPPLIED BY THE MANUFACTURER, SHALL
BE USED TO CONVERT THIS UNIT HEATER TO THE ALTERNATE
FUEL.
in identifying replacement part numbers. Always give the full Model No., Serial No., and Part No.
with description when ordering replacement parts.
COMMON REPLACEMENT PARTS FOR:
MODEL:
FE100
SERIAL NUMBER:
BAA65W7N12345
WHEN ORDERING PARTS, ALWAYS GIVE THE FULL MODEL NUMBER AND SERIAL
NUMBER.
Fan or Blower Motor .........95548
Fan Blade .........................41004
Fan Control .......................123976
Limit Control .....................45602
Transformer ......................131988
Pilot ...................................97534
Gas Valve .........................170609
Heat Exchanger ................102285
WARNING
ALL PARTS ARE FOR USE WITH THE FUEL IDENTIFIED ON THE UNIT RATING PLATE. IF
THE UNIT HAS BEEN CONVERTED TO OTHER FUELS, CHECK WITH THE DEALER FOR
PROPER FUEL-CARRYING PARTS. INSTALLATION OF IMPROPER PARTS CAN CAUSE
DEATH OR INJURY OR PROPERTY LOSS.