Form P-F/B (01-8-15), P/N 272436R5, Page 2

Example of a

Replacement Parts Tag

Replacement parts tags on unit

heaters are for your convenience

Example of a Rating Plate

Serial No. Explanation

Example:

BMC

94 9B

N

12345

1

2 3 4 5

Key:

1 = Date of manufacturer (see table on page 3)

2 = Type of Pilot (Refer to Form P-VALVES)

3 = Gas Valve (Refer to Form P-VALVES)

4 = Type of Gas (N = Natural; L = Propane)

5 = Consecutive number of heater made

(identification only)

Model No. Suffixes:

-S = Stainless steel heat exchanger

-2 = Two-stage gas valve

-E = Intermittent spark Ignition (NOTE: Spark

ignition required on all units effective 8/2008.)

-H = Factory equipped for high altitude operation

(NOTE: A change in 2004 allowing altitude

adjustment in the field eliminated the high-altitude

factory-equipped options.

Key to Rating Plate Information:

B = Model No. (Size)

C = Month and Year of Manufacture

D = Volts, Phase, Hertz and Maximum Total Input Amps

E = Type of Gas (Natural or Propane)

F = Burner Orifice Size

G and H = Elevation in Feet and Meters

I = Normal Input (BTUH) at Sea Level

J = BTUH Input Adjusted for Altitude

K = Thermal Output Capacity (BTUH) at Sea Level

L = BTUH Output Adjusted for Altitude

M = Minimum Input (BTUH) at Sea Level

N = BTUH Minimum Input Adjusted for Altitude

O = Normal Manifold Pressure (in. w.c.)

P = Minimum Gas Supply Pressure (in w.c.)

Q = Top Clearance (inches)

REZNOR

®

MERCER, PA. USA 16137

MADE IN MEXICO
UNIT

HEATER

NRTL

CATEGORY I

FOR INDUSTRIAL/COMMERCIAL USE ONLY

ANSI Z83.8 [

AA ] - [ A ] CSA 2.6 [ AA' ] - [ A' ] UNIT HEATER

MODEL [ B ] [ C ]

SERIAL NO.

[ D ] VOLTS [ D ] PH [ D ] HZ MAXIMUM TOTAL INPUT [ D ] AMPS

TYPE OF GAS: [ E ]

ORIFICE SIZE [

F ] DRILL HAS BEEN FACTORY ADJUSTED FOR USE

AT [

G ] FEET [ H ] METERS OF ALTITUDE.

SEA

LEVEL

ALT.

ADJUSTED

NORMAL INPUT

[

I ]

[

J ]BTU/HR.

THERMAL OUTPUT CAPACITY

[

K ]

[

L ]BTU/HR.

MINIMUM INPUT (-2 MODELS)

[

M ]

[

N ]BTU/HR.

NORMAL MANIFOLD PRESSURE

[

O ] IN.W.C.

MIN. PERMISSIBLE GAS SUPPLY PRESSURE FOR PURPOSE OF

INPUT ADJUSTMENT.

[

P ] IN.W.C.

CLEARANCES TO COMBUSTIBLE CONSTRUCTION: TOP-[

Q ],

FLUECONNECTION-6", LEFT SIDE-18", RIGHT SIDE-18",

BOTTOM-12" EXCEPT WHEN SUPPLIED WITH OPTIONAL

DOWNTURN NOZZLE BOTTOM IS 42"

FOR ALTERNATE INSTALLATIONS USE THE LATEST EDITIONS

OF THE APPROPRIATE STANDARD LISTED BELOW / INSTALL

IN ACCORDANCE WITH REQUIREMENTS OF ENFORCING

AUTHORITIES:

FOR AIRCRAFT HANGARS

USE STANDARD ANSI/NFPA 409

FOR PARKING STRUCTURES

USE STANDARD ANSI/NFPA 88A

FOR REPAIR GARAGES

USE STANDARD ANSI/NFPA 88B

THIS UNIT IS NOT FOR USE WITH DUCTS.

THIS UNIT IS NOT FOR USE WITH FILTERS.

THIS UNIT IS FOR USE WITH NATURAL GAS AND PROPANE. A

CONVERSION KIT AS SUPPLIED BY THE MANUFACTURER, SHALL

BE USED TO CONVERT THIS UNIT HEATER TO THE ALTERNATE

FUEL.

in identifying replacement part numbers. Always give the full Model No., Serial No., and Part No.

with description when ordering replacement parts.

COMMON REPLACEMENT PARTS FOR:

MODEL:

FE100

SERIAL NUMBER:

BAA65W7N12345

WHEN ORDERING PARTS, ALWAYS GIVE THE FULL MODEL NUMBER AND SERIAL

NUMBER.
Fan or Blower Motor .........95548
Fan Blade .........................41004
Fan Control .......................123976
Limit Control .....................45602
Transformer ......................131988
Pilot ...................................97534
Gas Valve .........................170609
Heat Exchanger ................102285

WARNING

ALL PARTS ARE FOR USE WITH THE FUEL IDENTIFIED ON THE UNIT RATING PLATE. IF

THE UNIT HAS BEEN CONVERTED TO OTHER FUELS, CHECK WITH THE DEALER FOR

PROPER FUEL-CARRYING PARTS. INSTALLATION OF IMPROPER PARTS CAN CAUSE

DEATH OR INJURY OR PROPERTY LOSS.