16

figure 10. Wiring diagram for S4Bd Single phase models

(1.5, 2, 2.5, 3, 3.5, 4, & 5 ton units)

Single Phase

1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs en cuivre.
3. Ne convient pas aux installations de plus de 150 volt a la terre.

710388B

(Replaces 710388A)

0109

WIRING DIAGRAM

Split System Air Conditioner (Outdoor Section)

NOTES:

1. Disconnect all power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150 volts to ground.
4. For replacement wires use conductors suitable for 105 deg C.
5. For ampacities and overcurrent protection, see unit rating plate.
6. Connect to 24 vac/40ca/class 2 circuit. See furnace/airhandler installation
instructions for control circuit and optional relay/transformer kits.
7. Anti-Short Cycle Timer (ASCT) may or may not be installed in the unit. If desired,
ASCT is factory installed on select models only or may be field installed as shown using
manufacturer’s approved kit. If not present, connect Yellow and Black wires per Note 6.

FIELD WIRING

LEGEND:

LOW VOLTAGE

HIGH VOLTAGE

¢710388B¤

CC - Contactor Coil
CCH - Crankcase Heater
HPS - High Pressure Switch

208/230V

CC

ASCT

ASCT

(SEE NOTE 7)

H

C

F

CCH

(OPTIONAL)

R

C

S

S

C

R

L2

T2

COMPRESSOR

CONTACTS

L1

T1

COMPRESSOR

OUTDOOR FAN
MOTOR

24 VOLT FIELD
CONNECTIONS

HPS

HPS

T2

T1

T3

ASCT

(SEE

NOTE 7)

GROUNDING

SCREW

L1 L2 GND

T1

T2

L1

L2

OUTDOOR

FAN MOTOR

C

S

DUAL

CAPACITOR

R

3

1

2

START

CAPAC

START

RELAY

BLACK

BLUE

ORANGE

YELLOW

CONTACTOR

YELLOW

BLACK

RED

CRANKCASE

HEATER

(OPTIONAL)

YELLOW

BLACK

SEE NOTE 6

RED OR

YELLOW

BLACK

RED OR

RED BLACK

BLACK OR

BLK WHT

C

S

R

YELLOW

OR

YELLOW

BLACK

RED OR

RED BLACK

H

C

F