Venter specifications, Components (cont'd), Electrical – Reznor X Option - Option - Installation - Power Venter User Manual
Page 2: Control system, Venteradapters

Form I-X Venter, P/N 136958R1, Page 2
4 Round
Oval 6 Round Equivalent
2-3/16
2-1/2
4 Round
Oval 7 Round Equivalent
4 Round
Oval 8 Round Equivalent
3
4
4 Round
8 Round
4 Round
4 Round
2
2
4 Round
Oval 5 Round Equivalent
4 Round
5 Round
2
2-3/16
6 Round
4 Round
Venter
Specifications
FIGURE 1 - Adapter Application, P/N's, and Dimensions
Model
P/N
Dimensions
Model
P/N
Dimensions
Model
P/N
Dimensions
XL, XLB,
CXL,
CXLB 30,
45, 60
6838
XL, XLB,
CXL, CXLB
105
20901
X, XE, CX,
CXE 250,
300
12731
XL, XLB,
CXL,
CXLB 30,
45, 60
6534
X, CX, XE, CXE
125;
XL, XLB 125,
140;
CXL, CXLB
140, 170
6539
XL, XLB,
CXL, CXLB
300
24017
X, CX,
XE, CXE
75
14516
X, XE 150,
175;
CX, CXE 175;
XL, XLB 150,
170, 200;
CXL, CXLB
150, 200
6542
X, XE 350,
400; CX,
CXE 400;
DX 300
12732
X, CX,
XE, CXE
100
6536
X, XE 200, 225;
CX, CXE 225;
XL, XLB, CXL,
CXLB 225, 250
12730
XL, XLB,
CXL, CXLB
350, 400;
CX, CXE
350
46163
Components (cont'd)
Packages that Apply to Models
(C) XL (B)
XL,XLB 125/140;
CXL,CXLB 140/170
XL,XLB 150/170/200;
CXL,CXLB 150/200
(C) XL (B)
30/45/60 75
105
225/250
300
350/400
Package P/N's by Option
(CA) Designation and
Voltage for obsolete Models
XL/XLB/CXL/CXLB
CA1-115V There are no kits for
these sizes. Order
Parts listed below.
136961
136962
136963 There are no kits
for these sizes.
Order Parts listed
below.
CA2-208V
136968
136969
136970
CA3-230V
136975
136976
136977
CA4-460V
136982
136983
136984
Components (For sizes that do not have packages available, the order components separately by size and voltage.)
Venter Sub Assembly
CA1
29992
29992
29992
29994
CA2
30229
30229
30229
30233
CA3
30231
30231
30231
30235
CA4
29992
29992
29992
29994
Transformer .25KVA,
460 to 115
CA4 only
11279
11279
11279
Venter Flue Adapter
CA1,2,3,4
6838 6534 20901
6539
6542
12730 24017
46163
Electrical
Option
No.
for
Heater
Sizes
Venter
Sub-
Assy
Voltage
Amps
Ship
Wt
(lbs)
NOTES:
Control *Motor FLA LR
*Two pole motor, nominal
3000 RPM - Maximum per-
missible voltage for 115 volt
venter motor is 127 volts;
208 volt is 228 volts; and
230 volt is 250 volts.
** Option CA4 includes a
transformer.
CA1 &
CA4**
30-300 29992
24
115
1.4 1.94
11
350-400 29994
12
CA2
30-300 30229
208
0.72 0.95
11
350-400 30233
12
CA3
30-300 30231
230
0.7 0.94
11
350-400 30235
12
Control System
A pressure switch starts and stops the burner. Low voltage control includes a built-in
relay. Thermal switch provides post-purge.
VenterAdapters
The adapter designed and tested for the particular model and size of Reznor
®
heater
must be used to connect the venter to the heater flue. The venter controls the volume
of dilution air flow through the drafthood and vent pipe, providing for safe and efficient
operation. See adapter dimensions in
FIGURE 1.