beautypg.com

Venter specifications, Components (cont'd), Electrical – Reznor X Option - Option - Installation - Power Venter User Manual

Page 2: Control system, Venteradapters

background image

Form I-X Venter, P/N 136958R1, Page 2

4” Round

Oval 6” Round Equivalent

2-3/16”

2-1/2”

4” Round

Oval 7” Round Equivalent

4” Round

Oval 8 ” Round Equivalent

4” Round

8” Round

4” Round

4” Round

4” Round

Oval 5” Round Equivalent

4” Round

5” Round

2-3/16”

6” Round

4” Round

Venter

Specifications

FIGURE 1 - Adapter Application, P/N's, and Dimensions

Model

P/N

Dimensions

Model

P/N

Dimensions

Model

P/N

Dimensions

XL, XLB,

CXL,

CXLB 30,

45, 60

6838

XL, XLB,

CXL, CXLB

105

20901

X, XE, CX,

CXE 250,

300

12731

XL, XLB,

CXL,

CXLB 30,

45, 60

6534

X, CX, XE, CXE

125;
XL, XLB 125,

140;

CXL, CXLB

140, 170

6539

XL, XLB,

CXL, CXLB

300

24017

X, CX,

XE, CXE

75

14516

X, XE 150,

175;

CX, CXE 175;

XL, XLB 150,

170, 200;

CXL, CXLB

150, 200

6542

X, XE 350,

400; CX,

CXE 400;
DX 300

12732

X, CX,

XE, CXE

100

6536

X, XE 200, 225;

CX, CXE 225;

XL, XLB, CXL,

CXLB 225, 250

12730

XL, XLB,

CXL, CXLB

350, 400;

CX, CXE

350

46163

Components (cont'd)

Packages that Apply to Models

(C) XL (B)

XL,XLB 125/140;

CXL,CXLB 140/170

XL,XLB 150/170/200;

CXL,CXLB 150/200

(C) XL (B)

30/45/60 75

105

225/250

300

350/400

Package P/N's by Option

(CA) Designation and

Voltage for obsolete Models

XL/XLB/CXL/CXLB

CA1-115V There are no kits for

these sizes. Order

Parts listed below.

136961

136962

136963 There are no kits

for these sizes.

Order Parts listed

below.

CA2-208V

136968

136969

136970

CA3-230V

136975

136976

136977

CA4-460V

136982

136983

136984

Components (For sizes that do not have packages available, the order components separately by size and voltage.)

Venter Sub Assembly

CA1

29992

29992

29992

29994

CA2

30229

30229

30229

30233

CA3

30231

30231

30231

30235

CA4

29992

29992

29992

29994

Transformer .25KVA,

460 to 115

CA4 only

11279

11279

11279

Venter Flue Adapter

CA1,2,3,4

6838 6534 20901

6539

6542

12730 24017

46163

Electrical

Option

No.

for

Heater

Sizes

Venter

Sub-

Assy

Voltage

Amps

Ship

Wt

(lbs)

NOTES:

Control *Motor FLA LR

*Two pole motor, nominal

3000 RPM - Maximum per-

missible voltage for 115 volt

venter motor is 127 volts;

208 volt is 228 volts; and

230 volt is 250 volts.

** Option CA4 includes a

transformer.

CA1 &

CA4**

30-300 29992

24

115

1.4 1.94

11

350-400 29994

12

CA2

30-300 30229

208

0.72 0.95

11

350-400 30233

12

CA3

30-300 30231

230

0.7 0.94

11

350-400 30235

12

Control System

A pressure switch starts and stops the burner. Low voltage control includes a built-in

relay. Thermal switch provides post-purge.

VenterAdapters

The adapter designed and tested for the particular model and size of Reznor

®

heater

must be used to connect the venter to the heater flue. The venter controls the volume

of dilution air flow through the drafthood and vent pipe, providing for safe and efficient

operation. See adapter dimensions in

FIGURE 1.