Reznor X Option - Option - Installation - Power Venter User Manual
Description/ application, Components, Products only

Form I-X Venter, P/N 136958R1, Page 1
1. DANGER: Failure to comply will result in severe personal injury or death
and/or property damage.
2. WARNING: Failure to comply could result in severe personal injury or
death and/or property damage.
3. CAUTION: Failure to comply could result in minor personal injury and/or
property damage.
Installation, Operation, and Parts for Power Venter,
Options CA1, CA2, CA3, and CA4
Form I-X Venter (Version A)
Obsoletes Form I-X/XE Venter
Applies to
:
Model X Duct Furnace plus
Obsolete Models (H)CX, DX,
(H)XE, (H)CXE, (C)XL, and (C)XLB
WARNING
Improper installation, adjustment, alteration, service, or maintenance can cause property
damage, injury or death. Read the installation, operation, and maintenance instructions
thoroughly before installing or servicing this equipment.
Description/
Application
WARNING
Optional power venter and venter flue adapter are designed for
USE WITH THESE DESIGNATED REZNOR
®
PRODUCTS ONLY.
•
DO NOT install these power venters on any other Reznor
®
equipment
including Reznor
®
Model F and Model B gravity-vented unit heaters. Use only
the power venting kits that are especially designed for F and B Models.
•
DO NOT install these venters on equipment not manufactured with the
Reznor
®
brand.
*Models with prefix "H" are not listed separately throughout this form. Information for corresponding
"standard" model applies to the "H" model.
** Power venter cannot be installed on XLB/CXLB Sizes 30-105 when equipped with an optional blower
cabinet.
The Option CA power venter is a motorized vent exhauster designed to permit the
installation of a gravity-vented heater in an area of negative pressure up to 0.15" w.c.
or where horizontal venting is required. The venter assembly in this instruction form is
designed for and may
only be installed on the Reznor equipment listed below.
Use with Reznor
®
Models Description
X/DX/HX*; CX/HCX*
Duct Furnace
XE/HXE*; CXE/HCXE*
Packaged Duct Furnace & Blower
XL/CXL; XLB/CXLB**
Fan & Blower Type Unit Heaters
HAZARD INTENSITY
LEVELS used in these
instructions
Components
Option packages are listed for currently manufactured Model X duct furnaces. Obso-
leted models are also listed where applicable. Review carefully and verify that the parts
are correct for the heater being serviced.
Packages Apply to Models X/DX
1
/CX
2
/XE/CXE
2
75
100
125
150-175
200-225
250-300
1
350
2
-400
Package P/N's by Option
CA Designation and
Voltage for Models
X/DX/CX/XE/CXE
Option CA1-115V
136959 136960 136961 136962
136963
136964
136965
Option CA2-208V
136966 136967 136968 136969
136970
136971
136972
Option CA3-230V
136973 136974 136975 136976
136977
136978
136979
Option CA4-460V
136980 136981 136982 136983
136984
136985
136986
Components
In Option(s)
Component P/N's
Venter Sub Assembly
CA1
29992
29994
CA2
30229
30233
CA3
30231
30235
CA4
29992
29994
Transformer .25KVA
CA4 only
11279 (460 to 115)
Venter Flue Adapter
All (CA1,2,3,4)
14516
6536
6539
6542
12730
12731
12732
2
1
For Model DX300, select package for Model X400.
2
Package P/N's listed
do not apply to Model CX350 or Model CXE350. These
models require the same components as listed for a Size 350
except the venter flue adapter is different. Venter Flue Adapter
required is
P/N 46163.
®