32

DMX512 REFERENCE GUIDE

DMX200 Interface

The DMX200 interface unit provides control of Series 200 luminaires
from a DMX512 console.

+

Converts DMX512 protocol to DMX200 data.

+

Receives power from and supplies data to the ACS rack through a
special power/data "Y" cable.

+

Supports up to one bi-channel ACS rack using two universes of
DMX512.

+

Designed to fit standard rack mount boxes or the modular rack.

DMX Power Pack and DPP Plus

The DMX Power Pack (DPP) is a portable electronics chassis that provides
lamp power, and translates DMX512 protocol to Series 300 luminaire
protocol. There are two versions of the DPP; one for arc lamps and one for
incandescent lamps. The two versions of the DPP are indicated with either
an APS6 or C3 module markings on the unit’s front panel.

Two versions of the unit are available: a standard DPP unit and a DPP plus
unit. The standard unit can operate any of the Series 300 luminaires with
the exception of the VL7 Series luminaires, which can only be operated with
a DPP plus unit.

The DPP Plus includes a power supply and APS6 suitable for powering the
VL7 Series luminaires.

Note: A label at the input panel specifies APS6 or C3.

Dimmers

If there are VL5 luminaires in your system, you will also need to supply power to the dimmers that are associated with
these luminaires. This is not a concern if you are using the house dimming system. However, if you are adding
dimmers to your system, or are setting up all the elements of your event, you will need to power your dimmers. In
general, most dimmers require three-phase power for operation. You should consult the operating manual provided
by your dimmer manufacturer for the proper power requirements for your dimmers.

In addition, some dimmer manufacturers reverse the ground and neutral Cam-Lok connectors on their product. You
may need to provide for specific adapters between equipment. Again, consult the manufacturer or their authorized
representative for plugging options and adapters.

In most cases, unless specifically requested, you will not receive APS6 cable (AKA Shielded Socapex cable) with the
rental of VL5 wash luminaires, unless your rental includes C3 modules and/or dimmers. Speak with your Account
Manger for equipment specifics. If the VARI

LITE Series 200/300 system is being installed into an existing light plot,

the Smart Repeater units may plug directly into circuits on electrics or battens using a "fan-in"; a male stage pin (or
other male plug) to female Socapex adapter. You may need to supply Socapex multicore and breakouts as
necessary.