PRG DMX Reference Guide 5.4 User Manual
Page 112

104
DMX512 REFERENCE GUIDE
Table 4-13: Manual Tests
Test Number
Test Parameter
Test Result
21
End-of-Travel Sensors
2
Read Tilt Sensor (VLM)
Static = Closed Sensor
5
Read Dimmer Sensor (VL6)
Flashing = Open Sensor
6
Read Color 1 Sensor (VL6)
7
Read Color 2 Sensor (VL6)
22
Pan Encoder
9
Select MSD
Display Digit
23
Tilt Encoder
8
Select 2SD
Display Digit
7
Select 3SD
Display Digit
6
Select LSD
Display Digit
0
Snap shot
Scroll Digits
24
Form And Function
Display Form And Function
Value
VL5: F=7
VLM: F=8
VL6: F=9
25
Data Loop-Back
9
External
Pass= 0 (Zero)
8
Internal
Fail = E
26
Color 1 Step Mode
Increment = 1 Step CW
Static = Closed Sensor
Decrement = 1 Step CCW
Flashing = Open Sensor
27
Color 2 Step Mode
Increment = 1 Step CW
Static = Closed Sensor
Decrement = 1 Step CCW
Flashing = Open Sensor
Table 4-14: Program Mode Selection
Test Number
Test Parameter
Error Codes/Comments
30
Enter PGM Mode
Parameters do not store
with tests.
Indicates test number for selection:
flashing for deselection, P if invalid
test number.
9
Synchronized
Error code displays during test
31
Test Program
8
Unsynchronized
32
Test Program
7
Sequential Mode 5 min.
33
Test Program
6
Sequential Mode 2 min.
34
Test Program
5
Sequential Mode 1 min.
35
Test program
4
Sequential Mode 45 sec.
36
Test Program
3
Sequential Mode 30 sec.
37
Test Program
2
Sequential Mode 20 sec.
38
Test Program
1
Sequential Mode 10 sec
39
Test Program
0
Sequential Mode 5 sec.