beautypg.com

Caution warning, Important – Oakworks ProLuxe Series User Manual

Page 14

background image

DIRECTIONS

FOR

USE

DIRECTIONS FOR USE

MOVING THE TABLE

Grasp the table frame

securely here at both

sides of the brace.

Before moving any of the
Tables, disconnect the power
cord from the power outlet.

IMPORTANT

Be sure to grasp the frame at
the brace between the two legs
of the frame on the end with
the self-locking molded rub-
ber feet to allow the wheels to
move.

The table is equipped with two wheels at one end and two self-lock-

ing, molded rubber feet at the other. When ready to move the table,

first lower the table to its lowest position. On models with a backrest, it

is recommended to raise the back rest to a high position. Then be

sure the power source is disconnected. Place the cord out of the

way on top of your table before moving the table.
Pick up all controls and lay them on the center of the table. Lay a

towel or a cloth down on your table top to protect the surface from any

debris from the bottom of your foot controls.
Two people are needed to safely move the table. Grasp the table

at the brace between the molded rubber feet at that end of the

table. By grasping the table frame firmly at this point, you can raise

the table to allow the wheels at the foot end to move freely. Use proper

positioning when raising the table by bending at the knees before lifting.

This prevents back strain or possible injury.

The table weighs as much as
175 lbs. Use extreme caution
when lifting the table to move
it. Two people are needed to
move the table safely. Be sure
to bend from the knees to prevent
back strain and possible injury.

DO NOT move the table with
client still on the table.

Move the table carefully to the next location, lower the table and

release. Check the self-locking molded rubber feet to be sure they

are flat side down. This position “locks” the table and allows sturdy

height adjustments. Place the foot controls in position on the floor.

Connect the power cord to the outlet and test the foot controls.

CAUTION

WARNING

A more convenient way to move the table from room to room

(without a patient) is with the dual caster option. Unlock the four

casters and maneuver the table to your desired location. The table

can be pushed from either end. Make sure to lock at least one caster

from each side prior to use by a patient. The Dual Caster option

was designed to enable small table positioning with the patient still

on the table, but do not attempt to move the patient from room to

room while on the table.

OPTIONAL DUAL CASTERS

unlocked

locked

11