Maxim Integrated 71M6534 Energy Meter IC Family Software User Manual
Page 73

71M653X Software User’s Guide
Vbat
Last measured battery voltage.* (Note: battery
voltage is measured once per day, except
when it is being displayed).
]7 / (2^9) (ADC counts,
logically shifted right 9 bits)
)22 unsigned 32
Vrms_A
Vrms, element A
sqrt(v0sqsum)*(2
16
) )24
unsigned
32
Irms_A
Irms, element A
sqrt(i0sqsum)*(2
16
) )25
unsigned
32
Vrms_B
Vrms, element B**,†
sqrt(v1sqsum)*(2
16
) )26
unsigned
32
Irms_B
Irms, element B
sqrt(i1sqsum)*(2
16
) )27
unsigned
32
Vrms_C
Vrms, element C‡
sqrt(v2sqsum)*(2
16
) )28
unsigned
32
Irms_C
Irms, element C‡
sqrt(i2sqsum)*(2
16
) )29
unsigned
32
Status
Status of meter
Bits:
See table below.
)2A unsigned 32
CAI
Count of accumulation intervals since reset, or
last clear (“)1=2”)
count )2b
signed
32
Whi**
Imported Wh, all elements.
LSB of w0sum
)2c
signed
64
Whi_A**
Imported Wh, element A
“
)2e
signed
64
Whi_B**
Imported Wh, element B
“
)30
signed
64
Whi_C**‡
Imported Wh, element C
“
)32
signed
64
VARhi*
Imported VARh, all elements.
LSB of w0sum
)34
signed
64
VARhi_A
Imported VARh, element A
“
)36
signed
64
VARhi_B
Imported VARh, element B
“
)38
signed
64
VARhi_C*‡
Imported VARh, element C
“
)3A
signed
64
VAh**
Volt-amps, all elements.
LSB of w0sum
)3C
signed
64
VAh_A**
Volt-amps, element A
“
)3e
signed
64
VAh_B**
Volt-amps, element B
“
)40
signed
64
VAh_C**‡
Volt-amps, element C
“
)42
signed
64
Whe**
Exported Wh, all elements.
LSB of w0sum
)44
signed
64
Whe_A**
Exported Wh, element A
“
)46
signed
64
Whe_B**
Exported Wh, element B
“
)48
signed
64
Whe_C**‡
Exported Wh, element C
“
)4A
signed
64
VARhe**
Exported VARh, all elements.
LSB of w0sum
)4C
signed
64
VARhe_A**
Exported VARh, element A
“
)4e
signed
64
VARhe_B**
Exported VARh, element B
“
)50
signed
64
VARhe_C**‡ Exported VARh, element C
“
)52
signed
64
Whn
Net metered, all elements
LSB of w0sum
)54
signed
64
Whn_A
Net metered Wh, element A, for autocalibration “
)56
signed
64
Whn_B
Net metered Wh, element B, for autocalibration “
)58
signed
64
Whn_C‡
Net metered Wh, element C, for autocalibration “
)5A
signed 64
VARhn
Net metered VARh, sum, all elements
LSB of w0sum
)5c
signed
64
VARhn_A
Net metered VARh, element A, for
autocalibration
“ )5e
signed
64
v1.1v1.1
TERIDIAN Proprietary
73 of 116
© Copyright 2005-2008 TERIDIAN Semiconductor Corporation