71M653X Software User’s Guide

PulseWidth

Maximum time pulse
is on.

microseconds =
(2*PulseWidth + 1)*397,
0xFF disables this feature.
Takes effect only at start-up.

50

10ms

)13 signed 16

temp_nom

Nominal temperature,
the temperature at
which calibration
occurs.

Units of TEMP_RAW, from
CE.

0x408D1800

847662 (6531)
0x3DCC7800
(6533, 6534)

From a real PCB at
23C

)14 unsigned 32

ImaxB

1

Scaling Maximum
amps for PCB
element B

0.1A

2080

208.0A

)15 unsigned 16

ncount

2

The time that neutral
current can exceed
INThrsld before the
neutral bit is
asserted.

Count of accumulation
intervals

10, ~10 secs

)15

unsigned

16

Starting current,
element B

sqrt(i0sqsum)*(2

16

)

513421

(6531)

433199 (6533 &
6534)

0.08A, same
rationale as
Ithrshld

)16 unsigned 32

IThrshldB

1

Maximum valid
neutral current

sqrt(i0sqsum)*(2

16

)

641776

0.1A

)16 unsigned

INThrshld

2

32

VBatMin

Minimum valid battery
current.

Same as Vbat, below

0x00E54D4C

(6531)

0x00723D00 (6533
& 6534)

2V on a real PCB;
should be adjusted
for battery and
chip.

)17 unsigned 32

CalCount

Count of calibrations

Counts number of times
calibration is saved, to a
maximum of 255.

)18

unsigned

8

RTC copy

Nonvolatile copy of
the most recent time
the RTC was read.

Sec, Min, Hr, Day, Date,
Month, Year

)19,

1A,
1B,
1C,
1D,
1E,

1F

unsigned

8

each

deltaT

Difference between
raw temperature and
temp_nom

Units of TEMP_RAW, from
CE.

)20,

signed

32

Frequency

Frequency

Units from CE.

)21

unsigned

32

v1.1v1.1

TERIDIAN Proprietary

72 of 116

© Copyright 2005-2008 TERIDIAN Semiconductor Corporation