1. Introduction

Thank you for choosing the SAUTER FL series instrument.
With correct use and regular re-calibration it will give many
years of accurate and reliable service.
The FL can measure tensile and compressive forces
accurately, being simply used by the operator. It may be
used handheld or mounted on a fixture or test stand.
SAUTER offers software and accessories to make the
force gauge even more versatile. Ask your SAUTER
distributor for additional information or visit our website at
www.kern-sohn.com

2. Before Use

After having received the unit please check that no
physical damage has occurred to the packaging material,
plastic case or the instrument itself. If any damage is
evident, please notify SAUTER immediately.

3. Operation Overview

The most common used features (such as displaying
force, peak hold, zero and changing of displayed units) can
all be done by pressing a single dedicated key identified on
the front panel-see the Basic Functions section.

You can press a menu key to access the gauge
configuration- see the Main Menu section.


4. Powering the FL

The FL is supplied with a set of 4 Nickel Metal Hydride AA
rechargeable batteries. For safety reasons during
transportation the batteries are shipped discharged. To
obtain maximum battery life we recommend that you
charge them with the charger/adaptor supplied for at least
14-16 hours when you first receive the instrument.

5. Battery Indicator

If battery level is less than 3.9 V, The “battery empty”
message will be displayed and the gauge will power down
automatically.
Important: Only use the adaptor/charger supplied

6. Fitting Accessories

Couple fittings directly to the load cell stem or use an
extension rod. The threads are 5mm and have capacities
up to 2500 N.
Ensure that the fixing does nor contact the force gauge
case. Ensure that anything coupled to the gauge is
screwed finger-tight only. Excessive torque can damage
the load cell and is not covered by warranty.

7. Mounting to a Fixture or Test Stand

The two 10-32 threaded holes, or fours 3mm thread holes
on the rear of the gauge can be used for mounting the
gauge. A versatile stand mounting plate is available to
couple the force gauge to many brands of test stands.

8. Powering up

As shown in Figure 1 the control panel has eight keys.



This manual is related to the following products: