Instruction Manual

SD

SD-BA-e-1213

1

Model: SD, Spring Tester














Thank you for buying a SAUTER Spring Tester. We hope
you are pleased with your high quality force gauge with its
big functional range. If you have any queries, wishes or
helpful suggestions, do not hesitate to call our service
number.

1.

Working Conditions


10°C to 30°C / 15% up to 80% humidity

2.

Operation


a.

Display

(1) Measuring Result
(2) Measuring Units
(3) Activation of PRINT Function
(4) Indication of power charging status
(5) PEAK or AUTO-PEAK Mode
(6) Average value of stored peak values
(7) Force direction
(8) Occupancy of storing spaces
(9) AVERAGE- or Saving Mode

b.

Operating keys


ON / OFF:

ON / OFF key

(For ON, press 1 sec.)



UNIT:

-

Press shortly:

Select unit:
N, kg or lb


ZERO:

Three functions:
-

Zeros the measuring result (Tara function)

-

Cleans the peak value (in Peak mode)

-

Saves a setting (in SET mode)


SET:

-

1 x Press: Upper Limit [HidT]. To change
press

: ▲ or ▼ (see section c.)

-

1 x Press: Lower Limit [LodT]. To change
press ▲ or ▼ (see section c.)

-

1 x Press: Minimum limit to save peak
values in the instrument’s memory.
[LE.SET].

Please see section „Min Limit

Peak Save“. To change press: ▲ or ▼
(Only in „Peak-Mode“active) (see section
g.)

-

1 x Press: Auto-Off Function. Turns the
instrument off after a here defined time
period in sec.

[P.OFF]. To change press: ▲

or ▼ (Only in „Battery-Mode“ active)


-

1 x Press: Peak-Freeze-Time [PE.2E /
A.PE / HoldT]: Time period in which a peak
value is being shown in the display in sec.
To change press: ▲ or ▼

1 x Press: Saves the Settings



PEAK:

Three functions
-

Track mode (continuous measurement)

-

Peak mode (capture of maximum values)

-

Auto-Peak mode, same as Peak-mode, only
without the „Min limit peak save“ function

HidT

Lo dT

LESET

P.OFF