11.4 Counting with counting system
(Display example)
Bulk material balance e.g. KERN
KFP
Reference balance KERN CFS
Here pieces of huge quantities will
be counted.
Due to its high resolution it is useful
for accurate determination of the
average piece weight.
Big parts (max > 3kg) are counted
on the weighing bridge.
Smallest parts (max < 3kg) are
counted on the precise KERN CFS.
If in the determination of the
average piece weight no such
high resolution is asked for as that
of the KERN CFS, the reference
formation can also be made in the
bulk material balance.
Counting with bulk material balance:
1. On the reference balance KERN CFS set average piece weight, see chap. 11.1.
or chap. 11.2.
2. Switch over balance with
(s. chap. 9.3)
3. Put empty vessel on the weighing plate of the bulk material balance KERN KFP
and tare.
4. Fill counted quantity in the vessel on the bulk material balance. The piece
number is shown in the display.
In order to avoid errors at the piece number determination, both balances
must be adjusted with the same acceleration due to gravity (see chap. 7). In
case of non-compliance counting errors will result!