beautypg.com

Entraguard bronze, Telephone entry residence guide – Keri Systems EntraGuard Bronze Residence Guide User Manual

Page 11

background image

EntraGuard Bronze

1530 Old Oakland Road, Suite 100

01911-003 Rev. C

San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]

Page 11 of 14

Telephone Entry

Residence Guide

SET THE RING MODE

Sets the ring pattern used
when a visitor requests entry.

Press .

Select the desired ring mode (default = 1).

-

Press

for three short rings - long pause

-

Press

for two medium rings - long pause

Press

. The unit emits a short high-pitched tone to

indicate the ring mode has been accepted. A high-low tone is
emitted if an invalid ring mode has been entered.

SET THE MAXIMUM
NUMBER OF RINGS

Sets the maximum number of
rings used when a visitor
requests entry.

Press .

Press

– the desired number of rings (default = 6).

Press

. The unit emits a short high-pitched tone to

indicate the number of rings has been accepted. A high-low
tone is emitted if an invalid number of rings has been entered.

SET GATE 1 RELAY
ACCESS CODE

Allows a user to activate the
gate 1 relay from the
residence telephone.

Press .

Press

– the desired relay access code (default = 9).

Press

. The unit emits a short high-pitched tone to

indicate the access code has been accepted. A high-low tone
is emitted if an invalid access code has been entered.

SET GATE 1 RELAY
TIMEOUT

Sets the amount of time the
gate 1 relay is activated.

Press .

Press

– the desired relay timeout value (default = 5

seconds).

Press

. The unit emits a short high-pitched tone to

indicate the timeout value has been accepted. A high-low
tone is emitted if an invalid timeout value has been entered.

Programming Command

Instructions