5 connecting a general purpose input, Gold quick s tart guide, Entraguard – Keri Systems EntraGuard Gold Quick Start User Manual
Page 11: Gold telephone entry controller
EntraGuard
®
Gold Telephone Entry Controller
1530 Old Oakland Road, Suite 100
01801-001 Rev. 2.2
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]
Page 11 of 32
EntraGuard
®
– Gold
Quick S
tart Guide
4.5
Connecting a General Purpose Input
The general-purpose input is used in conjunction with the programmable input/output feature of the Doors access
control software. There are two possible uses for the general-purpose input.
•
the master controller may be configured for either Global Unlock (see Figure 10) or Auxiliary A-door RTE (see
Figure 11)
•
the slave unit
1
can only be configured for Auxiliary A-door RTE (see Figure 11)
Make the following connections for a Global Unlock input. (For a master controller only.)
Figure 10: Global Unlock Input Connections
Make the following connections for an Auxiliary RTE A-door input.
Figure 11: Auxiliary A-Door RTE Input Connections
1. An EntraGuard Gold unit may only be used as a slave to a master EntraGuard Gold unit.