0 specifications, Section 02 - specifications, Entraguard – Keri Systems EntraGuard Platinum Quick Start User Manual
Page 5: Platinum telephone entry controller, Quick start guide
EntraGuard
®
Platinum Telephone Entry Controller
Quick Start Guide
Page 5 of 28
P/N: 01969-001 Rev. C
2.0
Specifications
Unit Dimensions (nominal)
•
13
7
/
8
inches high by 10
3
/
8
inches wide by 3
1
/
2
inches deep, including hinges
•
(35 cm by 27 cm by 9 cm)
Operating Temperature/Humidity Range
•
-20°F to 140°F (-29°C to 60°C)
•
0% to 90% Relative Humidity, non-condensing
Controller Power Requirements
•
12 VDC @ 1 A (Platinum controller ONLY)
•
12 VDC @ 2 A (Platinum with optional PXL controller)
Current Draw (for Platinum controller ONLY)
•
maximum current draw 750 mA for a controller
NOTE: If an electronic locking device (such as a magnetic lock, a door strike, or similar device) is to be driven by the
same power supply as the EntraGuard Platinum controller, please ensure the power supply provides enough current to
drive every device connected to that supply plus an adequate safety margin. AC power cannot be used.
NOTE: Isolation of power supplies may be required with high transient situations.
Controller Memory Retention
•
5 year lithium battery back up to support controller RAM and real-time clock
Output Relay Contact Rating
•
1 Amp @ 24 VDC
Output Device Configuration - 4 Outputs
•
Lock Relay Form C
•
Alarm Relay Form C
•
Auxiliary Relay #1
Auxiliary Relay #2
Input Device Configuration - 3 Inputs
•
Door Sense
normally closed
•
Request to Exit
normally open
•
Global Unlock
normally open (on master only), or
Auxiliary RTE A-Door
normally open
Users Allowed
•
5,000 tenants maximum
Event Storage Capacity
•
3,640 events