Setting the protocol, Table 6. protocols – Interlogix UltraView PTZ Dome Series User Manual
Page 35

Chapter 4
Camera assembly, shroud, dome
27
Setting the protocol
CyberDome II can use different protocols for communication. To select a protocol, you must set the protocol
DIP switches to the correct sequence of 1s (on) and 0s (off).
To set the protocol DIP switches to select a protocol, do the following:
1. Locate the protocol DIP switch block (Figure 23 on page 26).
2. Using Table 6, find the DIP switch sequence for the desired protocol and set the switches accordingly.
CyberDome II stores programming settings in NVRAM in both the housing and the PTZ module. If the
protocol switches are not set to one of the copy settings (01111 or 11111) and the two memories are different,
Memory flashes onscreen. When you first log onto the menu system, you will be asked which settings you
would like to use. For more information on protocol functionality with the CyberDome II camera, see
Appendix B,
Table 6.
Protocols
Protocol
Switch position
a
a.
1 = on, 0 = off.
Protocol
Switch position
Automatic selection
b
b.
The Automatic selection will automatically determine only the GE protocols (Digiplex, Impac, and ASCII).
00000
AD RS-422
01010
GE Digiplex RS-422 4800
10000
AD Manchester
10010
GE Impac RS-485 9600
01000
Bosch RS-232
00110
GE ASCII RS-422 9600
11000
Bosch biphase
10110
Pelco D autobaud
00100
Coaxitron
11110
Pelco P autobaud
10100
KD6
10001
Ultrak 9600
01100
Serial update 9600
11011
BBV
01110
Serial update 115200
00111
VCL
11100
Clear settings
10111
Panasonic
11010
Copy settings from PTZ to housing
01111
Vicon
00010
Copy settings from housing to PTZ
11111