3 Cable Connection

3.1 Multiple-function Composite Cable

The multiple-function composite cable includes the audio/video connection port, RS485

connection port, and alarm input/output port. Please refer to the indication label on the multiple-

function composite cable for detailed connection information.

Name

Function

A

485-A. It is to control dome built-in PTZ.

B

485-B. It is to control dome built-in PTZ.

485

GND Ground.

OUT

Reserved audio port. Audio output port.

GND

Reserved audio port. Ground port audio.

AUDIO

IN

Reserved audio port. Audio connection port.

GND Ground

port.

VIDEO

OUT

Video output port.

Name

Function

AC24V

24V power port. Connect to the power cable.

EARTH Ground

port.

AC24V

24V power port. Connect to power cable.

3.2 Alarm Cable Connection

1)

Please refer to the indication label on the multiple-function composite cable for detailed alarm

connection information.
2) Pleas refer to the following sheet for alarm input and output port information.

Name

Function

Alarm out:1-2

z

Two alarm output channels. When there is an alarm from current
channel, system activates relay or not.

z

Alarm output relay default setup is NO. You can use the jump-
cap near the power board relay to set.

z

NO:Normal open alarm output.

z

NC:Normal close alarm output.

GND

Alarm input ground end.

Alarm in:1-7

z

Seven alarm input channels. It is to receive relay signal from the
external alarm source. You can go to dome menu to activate
specified preset or patter.

z

When the activation mode is NO (normal open), dome alarms
when there is low voltage. High voltage will not activate the
alarm.