etc. You need to use a 120Ohm resistance between A/B cable if there are too

many PTZ decoder.

e) “

”:ground cable;



You can refer to the following sheet and Figure 3-6 for alarm input and output
information.

Parameter

Grounding Alarm

Ground Ground

line

Alarm Input

1, 2, …,4

Relay Output

1,2,3,4: NO and C(Normally Open and Com)

5: NO,C and NC(Normally Open, Com, Normally Closed)

6: Ctrl 12V(This is used for reset the senor)

485 A、B

485 communication port. They are used to control devices
such as PTZ.

+12(C)

This should input an external power input.

z

4-ch grounding alarm inputs. (Normal open or Normal close type)

z

Please parallel connect COM end and GND end of the alarm detector (Provide

external power to the alarm detector).

z

Please parallel connect the Ground of the DVR and the ground of the alarm detector.

z

Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)

z

If you need to reset the touched-off alarm remotely, you can use DVR to supply

controllable 12 V power to the alarm detector such as the smoke detector.

z

Use the same ground with that of DVR if you use external power to the alarm device.