Swash – Futaba 8FG 2.4GHz User Manual
Page 65

65
)XQFWLRQVRI/LQNDJH0HQX!
ŏ6HOHFW WKH IXQFWLRQ QDPH
and return to the Linkage
menu by touching the
RTN button.
SWASH
Swash AFR and linkage correction function. (helicopter only, except
swash type H-1)
1HXWUDO3RLQW
$W\RXUOLQNDJHVLIWKHVHUYRKRUQGHYLDWHVIURP
D SHUSHQGLFXODU SRVLWLRQ DW QHXWUDO WKH OLQNDJH
compensation functions in this menu may not
compensate effectively. To correct this use the
1HXWUDO3RLQWIXQFWLRQ7KLVZLOOPRYHWKHQHXWUDO
point of the servos to the actual perpendicular
SRVLWLRQ+RZHYHUWKLVDGMXVWPHQWFKDQJHVRQO\
the axis point of the compensation functions in this
PHQXDQGGRHVQRWDIIHFWWKHQHXWUDOSRVLWLRQRI
other functions.
6ZDVK$)5
6ZDVK$)5 IXQFWLRQ UHGXFHV LQFUHDVHV RU
UHYHUVHVWKHUDWHWUDYHORIWKHDLOHURQHOHYDWRUDQG
FROOHFWLYHSLWFKIXQFWLRQVE\DGMXVWLQJRUUHYHUVLQJ
WKHPRWLRQRIDOOVHUYRVLQYROYHGLQWKDWIXQFWLRQ
RQO\ZKHQXVLQJWKDWIXQFWLRQ
1HXWUDOSRLQWVHWWLQJSURFHGXUH
The neutral point becomes the correction
standard point.
$GMXVWLQJWKHVHUYRKRUQVRWKDWWKHQHXWUDOSRLQWLVQHDUWKH
50% position makes the mixing amount small.
1. Neutral point setting
Move the cursor to the [POS] item and hold
the pitch operation so that the servo horn is
at a right angle to the linkage rod and Touch
the RTN button for one second. This value
indicates the servo's neutral position.
After reading the neutral point, use the
other correction functions to make further
adjustments.
0L[LQJ5DWH
7KLVPL[LQJLVXVHGWRFRPSHQVDWHWKHVZDVK
plate as necessary during specific control inputs.
7KH IROORZLQJ FRPSHQVDWLRQ PL[LQJ LV SRVVLEOH
3,7WR$,/3,7WR(/($,/WR3,7(/(WR$,/
DQG(/(WR3,7+5PRGH,WDGMXVWVWKHVZDVK
plate to for proper operation of each control using
the corresponding compensation mixing.
/LQNDJH&RPSHQVDWLRQ
This compensation mixing is used to correct the
VZDVKSODWHIRUSLWFKFRQWURODWORZSLWFKDQGKLJK
pitch.
6SHHG&RPSHQVDWLRQ
This function is used to cancel the reaction that
is generated by the difference in the movements of
HDFKVHUYRZKHQWKHVZDVKSODWHPRYHV
6ZDVK$)5VHWWLQJSURFHGXUH
7KHVZDVK$)5IXQFWLRQPDNHVDGMXVWPHQWVVR
WKDWWKHVHUYRVWUDYHOWKHVSHFL¿HGDPRXQWE\>$,/@
>(/(@DQG>3,7@RSHUDWLRQ
1. Move the cursor to the function you want to
adjust and touch the RTN button to switch to
the data input mode.
2. Adjust the AFR rate by scrolling the touch
sensor.
,QLWLDO YDOXH
$GMXVWPHQW UDQJH a
:KHQWKH571EXWWRQLVWRXFKHGIRURQHVHFRQGWKH$)5
rate is reset to the initial value.
Touch the RTN button to end adjustment and
return to the cursor mode.
ŏ 6HOHFW >6:$6+@ LQ WKH /LQNDJH PHQX DQG DFFHVV
the setup screen shown below by touching the
RTN button.
Scrolling
ŏ0RYLQJ FXUVRU
ŏ6HOHFWLQJ PRGH
ŏ$GMXVWLQJ YDOXH
ŏ7R QH[W SDJH