13 speed estimation multi-channel system mcs-64 – Flintec MCS-64 ModbusOnEthernet User Manual
Page 34
Manual MCS-64: Modbus on Ethernet
Page 35
5.11 Filling Commands – PD1 to PD21, DI, SC, AC, GD, DT, SD
Remark: These commands are
only available in firmware 88.184.
Note: All setups should be stored with the SD command before power off.
A separate description of these commands is availble as pdf-file. Please contact
[email protected].
5.12 Loss in Weight Commands – PL1 to PL5, LC, LI, GF, GR, GM, SL
Remark: These commands are
only available in firmware 88.185.
Note: All setups should be stored with the SL command before power off.
A separate description of these commands is availble as pdf-file. Please contact
[email protected].
5.13 Speed Estimation Multi-Channel System MCS-64
Gateway Ethernet EGM 87.1
No. of Channels
Transfer Rate per Channel
Remark
8
40 values/sec *
* new firmware in gateway required
16
20 values/sec *
* new firmware in gateway required
32 10
values/sec
64 5
values/sec
This speed estimation is for example valid for gross / net weight.
For applications like check weighers, filling, loss in weight etc. each LDM 88.1 calculates the
valid result. This means that no “data stream” will overload the Ethernet traffic.
For a single channel, the data output via service port can be used for high speed measurements,
e.g. with the DOP software. The measuring rate is up to 600 measurement values/s.